For L-849I series circuit powered REILS, connect a 200W isolation transformer as shown in
.
•
For L-849V voltage powered REILS, connect 120/240Vac (3 wire) or 240Vac (2 wire) to TB1 as shown in
. Connect
an isolation transformer to the Primary unit if optional current sensing is used.
Table 5: L-849A/E, V/I, TB1 Terminal Functions - Control Cabinet 1 & 2
Terminal
Function
Note
TB1-1
Failure Indication Relay N.O. Contact
TB1-2
Failure Indication Relay Common Contact
TB1-3
Failure Indication Relay N.C. Contact
TB1-4
Remote Control – Identification ON
TB1-5
Remote Control – Low
A
TB1-6
Remote Control – Medium
A
TB1-7
Remote Control – High
A
TB1-8
Remote Control – 120Vdc Source
TB1-9
Remote control – 120Vdc Return
TB1-10
Trigger Input
TB1-11
Trigger Output
TB1-12
Spare
TB1-13
Spare
TB1-14
VAC Input
TB1-15
VAC Input
TB1-16
Neutral
TB1-17
Earth
TB1-18
Current Monitoring Option
B
TB1-19
Current Monitoring Option
B
NOTE A: L-849V/I, E Only
NOTE B: Used if optional current sensing is present
3.13 240Vac Powered REIL
Perform the procedure below if power for the REIL system is provided from a 120/240Vac split or 240Vac single phase power
supply.
To install 120/240Vac or 240Vac powered REIL, perform the following procedure:
1. Install interconnecting and control wiring as specified in Control Cabinet and Remote Control Wiring in this section.
2. Connect the 120/240Vac or 240Vac power supply lines to a customer-supplied external circuit breaker, if required.
3. Disengage the circuit breaker and connect power supply lines from the circuit breaker to terminal block TB1 terminals
labeled VAC IN-1 and VAC IN-2 in the cabinet.
4. Tighten all connections.
3.14 Installation Checkout
This subsection describes procedures for installation checkout. See the “Schematics” on page 27.
Wiring Checkout
REIL-L
Installation
20
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for REIL-L
Page 1: ...REIL L LED Runway End Identifier Light User Manual 96A0461 Rev H 2019 10 31 ...
Page 2: ......
Page 6: ...REIL L TABLE OF CONTENTS vi Copyright ADB Safegate All Rights Reserved ...
Page 8: ...REIL L List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...REIL L List of Tables x Copyright ADB Safegate All Rights Reserved ...
Page 18: ...REIL L Safety 8 Copyright ADB Safegate All Rights Reserved ...
Page 22: ...REIL L Introduction 12 Copyright ADB Safegate All Rights Reserved ...
Page 34: ...REIL L Installation 24 Copyright ADB Safegate All Rights Reserved ...
Page 38: ...REIL L Operation 28 Copyright ADB Safegate All Rights Reserved ...
Page 50: ...REIL L Maintenance and Repair 40 Copyright ADB Safegate All Rights Reserved ...
Page 60: ......