Menu for functions selection
By pressing
button, the instrument menu appears. If the instrument is in the error stage (for
example “SENSOR ERROR“), then some functions are not available.
LIGHT
- Torch mode
STROBO
- Stroboscope mode
VOLUME
- Phone output volume adjustment
SETUP
- This item opens next item selection:
SPEED
- Automatic speed detection ON or OFF
ALARMS
- Selection of standard, which will define limit values
UNIT
- Unit options for a measuring of a velocity signal (mm/s vs. ips)
- ESC -
- Return to the measuring screen
If the error is detected (e.g. “SENSOR ERROR"), then some item are not available. Move between
items by pressing
▼
▲
buttons. Select item by pressing
button. Use
- ESC
for return from Menu.
Fig.: Instrument MENU.
0
Fig. Meaning of the buttons
Fig.: Instrument MENU in error stage.
LIGHT
In LIGHT mode it’s possible to use instrument like the torch. Select the LIGHT mode and press
button. White LED built-in on the front side begins to light. Symbol of the torch appears on display.
Press any button to switch off the light and the instrument starts to measure again.
Fig.: Torch mode
Menu selection
buttons
MENU
Enter/escape
button