background image

EN

10 - WARRANTY

The warranty provided by the manufacturer Adam Pumps Spa covers the product for 2 years from the date of production.

Adam Pumps Spa (manufacturer) provides its customers with:
a warranty that covers problems resulting from production and conformity defects in the purchased products

the warranty period starts from the date indicated on the CE label which indicates the date of manufacture. A label indicating the date of manu-
facture will be applied to those products which are not provided with a CE label. Therefore, the warranty period will start from that date;
the warranty will become immediately null and void should the data of manufacture be illegible, for any reason, unless Adam Pumps Spa is 
responsible for this;
the warranty covers repairs or replacement of the product, in the event it cannot be repaired
repair operations can be carried out only by Adam Pumps or by Adam Pumps’ authorised centres;
the warranty will not be valid in the event the product is tampered with by unauthorised persons, bodies, and/or companies;
any warranty request is subject to approval by Adam Pumps. The goods can be returned only if provided with an authorisation code. Upon 
request, Adam Pumps will provide this code which will invoke the warranty for the product to be repaired or replaced
unless otherwise agreed with Adam Pumps, the returned goods must be sent via transport pre-paid by who has invoked the warranty to Adam 
Pumps Spa;
goods returned without authorisation and/or with transport not paid can be rejected;

The warranty will not be applied in the following cases

Failure to use or install the product according to Adam Pumps’ instructions

The product has been used with unauthorised fluids.
The product has been modified or tampered with
The product is used in an area with power supply defects (voltage changes, current phase shift, etc.)
The product is used without the supplied suction filter (inside or outside the pump).

Immediately excluded from the warranty are: adhesive labels, plastic and metal casing, keyboards and masks, components subject to wear 
such as blades, impellers, graphite brushes (where present in the motors), seals and gaskets in general.

11 - TECHNICAL SUPPORT

The Manufacturer is always available for any information required on installation, operation or maintenance of the machine. 

The Customer should ask the questions clearly, with reference made to this Manual and to the instructions listed. 

PARTS TO BE DISPOSED OF

DISPOSAL METHOD

PACKAGING

The packaging consists of biodegradable cardboard which can be sent to companies for 

normal pulp recycling.

METAL PARTS

The metal parts, whether painted or stainless steel, are usually recycled by companies special-

ised in the scrap metal industry.

ELECTRICAL AND ELEC-

TRONIC COMPONENTS

These must be disposed of by companies specialised in disposing of electronic components, 

in compliance with the requirements of Directive 2002/96/EC (see Directive text below).

PARTS OF A DIFFERENT 
NATURE

Other parts of the system in which the electric pump is installed, such as pipes, rubber gaskets, 
plastic parts and wiring, are to be given to companies specialised in disposing of industrial 
waste.

APPLICABLE REGULATIONS 

FOR CUSTOMERS IN THE 
EUROPEAN UNION

The European Directive 2002/96/EC states that the equipment bearing this symbol on the 

product and/or on the packaging is not to be disposed of with unsorted municipal waste. The 
symbol indicates that this product must not be disposed of with normal household waste. It 

is the responsibility of the owner to dispose of these products and the other electrical and 

electronic equipment through specific collection facilities appointed by the government or by 

local authorities.

Summary of Contents for PB 50

Page 1: ... 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com UM032 7 2020 rev 6 PB 50 PB1 50 12 24V PB 60 PB1 60 12 24V PB 85 PB1 85 12 24V ITALIANO lingua originale ENGLISH translation of original instructions IT EN ...

Page 2: ...ember States relating to the making available on the market of electrical equipment designed for use within certain voltage limits Applicable only for AC powered products the use and maintenance manual must be carefully stored near the machine in an environment protected against humidityandheat Themanualmustaccompanythemachineifsold Itisprohibitedtodamage modifyorremoveany part of the manual USE A...

Page 3: ... 40 PB1 85 12 V 12V DC 40 480 S2 30 min 85 1 1 70 40 PB 85 24 V 24V DC 32 768 S2 30 min 93 1 1 74 40 PB1 85 24 V 24V DC 32 768 S2 30 min 93 1 1 74 40 IMPORTANT It is essential to have understood the entire instruction manual before perfor ming any operation so as to safeguard operator safety and to avoid potential product damage Storing the manual This manual must be kept intact and fully legible ...

Page 4: ... the same diameter or a diameter larger than the minimum specified in chapter 3 INSTAL LATION always keep the filter inside the pump clean and regularly inspected 4 3 Storage Prior to its use the pump still in its original packaging should be stored in a dry and protected place in an environment with the conditions described in Section 2 1 Environmental conditions Failure to follow these instructi...

Page 5: ...itable for operation under negative pressure 5 3 Remarks on the suction lines SUCTION LINE The electric pumps in this manual are self priming and can draw the liquid from a maximum height of 2 metres Caution proper priming and the time required for this can be affected by an automatic nozzle on the discharge line which prevents normal air extraction from the pipe It is therefore always advisable t...

Page 6: ... and components on the hydraulic line are in good condition and properly sealed and the nozzle is closed the pump can be started After inserting the nozzle into the filling hole switch the pump on gradually release the nozzle lever and start transferring the diesel fuel When you have finished filling close the nozzle and switch the pump off If you are using an automatic nozzle it will automaticall...

Page 7: ...ed to operate correctly in an industrial electromagnetic environment and staying within the Emission and Immunity limits laid down in the following Harmonised Standards IEC EN 61000 6 2 Electromagnetic compatibility EMC Generic standards Immunity for industrial environments IEC EN 61000 6 4 Electromagnetic compatibility EMC Generic standards Emission standard for industrial environments 7 TROUBLES...

Page 8: ... and clean or replace it if necessary Vanes blocked Check and clean the vanes and their housings Excessive wear of the vanes or impeller Replace the worn components Leaks from the gaskets Make sure the gaskets are properly tightened and not worn Incorrect power supply voltage Power the pump as specified on the rating plate Defective motor Contact the dealer fault code M2 9 DEMOLITION AND DISPOSAL ...

Page 9: ...mpered with The product is used in an area with power supply defects voltage changes current phase shift etc The product is used without the supplied suction filter inside or outside the pump Immediately excluded from the warranty are adhesive labels plastic and metal casing keyboards and masks components subject to wear such as blades impellers graphite brushes where present in the motors seals a...

Page 10: ... PA018 SWIVEL LOCKING PLATE 1 15 11010040200 11010040200 O RING 2015 NBR 1 12V 24V DESCRIPTION QTY 16 82301410100 82301410100 SCREW TC M4 X 8 2 17 VT004 VT004 SCREW TC Ø3 5X16 4 18 12010031000 12010031000 SHAFT SEAL Ø19 1 19 VT046 VT046 SCREW TE M5X12 5 20 OR039 OR039 O RING NBR70 57X2 1 21 OR037 OR037 FILTER SEAL 1 22 17001108 17001108 4M CABLE WITH CLAMPS 1 23 61004600000 61004600000 TIE ROD M5 ...

Page 11: ... 11 53019030 CABLE GLAND NUT GMP GL 13 5 1 12 83101810000 PLATE WASHER 5x10x1 UNI 6592 2 13 82021810000 SELF LOCKING NUT M5 UNI 7473 2 14 190050210000 SWITCH 22X30 COVER 1 CODE DESCRIPTION QTY 15 PA018 SWIVEL LOCKING PLATE 1 16 VT046 SCREW TE M5X12 FLANGED UNI5541 5 17 11010040200 O Ring 2015 NBR 1 18 71000520 BY PASS VALVE 1 19 61000003 ROTOR Ø45 1 20 71000522 SMALL VANE 5 21 17001097 PIN 3x3x15 ...

Page 12: ...E Ø5X135 2 8 VT022 HEX SPACER MF M5X25 2 9 PB001 MOTOR COVER IP55 1 10 53015030 CABLE GLAND 1 11 53019030 CABLE GLAND NUT 1 12 83101817100 PLATE WASHER Ø5 2 13 82021810000 SELF LOCKING NUT M5 2 14 190050210000 SWITCH 22X30 COVER 1 CODE DESCRIPTION QTY 15 PA018 SWIVEL LOCKING PLATE 1 16 VT046 SCREW TE M5X12 FLANGED 5 17 11010040200 O Ring 2015 NBR 1 18 71000520 BY PASS VALVE 1 19 61000003 ROTOR Ø45...

Reviews: