POS.
DESCRIPTION
REFERENCE
QTY
230 Volts
115 Volts
1
STATOR MEC 63
232204000000
71009023
1
2
JUNCTION BOX SEAL 63/71-2
10501000000
1
3
CAPACITOR HOLDER Ø 10
140250100000
1
4
SCREW Ø 3,5 X 13
80801215000
10
5
CABLE FITTING
140250300000
1
6
SPACER WASHER Ø 4
80301400000
1
7
SCREW M4 X 8
82301410100
1
8
SWITCH 22 X 30
190050210000
1
9
SPADE CONNECTOR COVER 6,3
190110000000
6
10
JUNCTION BOX SEAL FKL 71
10502000000
1
11
CAPACITOR CLIPS
140250200000
1
12
BEARING 6201 2RS
101001600000
2
13
SHAFT ROTOR MEC 63
6290150000L
1
14
SPRING WASHER Ø 32
84500000000
1
15
FAN FLANGE MEC 63
15501600000X
1
16
HOUSING BOLT M5 X 125
61004600000
4
17
FAN MEC 63 WITH METAL RING Ø12
140250400000
1
18
FAN COVER MEC 63
140250500000
1
19
ELECTRIC BLACK CABLE
190200000000
190000190000
1
20
CAPACITOR
190060000000
190061000000
1
21
FLANGE
61715000000
61715000000
1
22
BY-PASS VALVE
71000520
71000520
1
23
PUMP HOUSING 60 LT 1”/ 1”
71000036
71000036
1
24
BY-PASS SPRING
16001005
16001005
1
25
BY-PASS CAP
71000521
71000521
1
26
O-RING 3118
18001008
18001008
1
27
METAL CAP 1”
17001094
17001094
1
28
SMALL PUMP FILTER
41140000
41140000
1
29
O-RING 132
11010200400
11010200400
1
30
METAL CAP 3/4”
17001006
17001006
1
31
“FILTER” STICKER
71000587
71000587
1
32
“CLEAN FILTER” STICKER
71000546
71000546
1
33
O-RING 2212
18001014
18001014
1
34
FLANGE PIN Ø4 X 14
91214140000
91214140000
1
35
ROTARY SEAL 10196
12010031000
12010031000
1
36
SHAFT KEY 3 X 3 X 15
17001097
17001097
1
37
PUMP ROTOR Ø45
61000003
61000003
1
38
VANE
71000522
71000522
5
39
SCREW M5 X 45
13001002
13001002
3
40
PLASTIC CAP Ø31
163013500000
163013500000
2
41
“DANGER” STICKER
71000653
71000653
1
42
“CE” STICKER
220000000000
220000000000
2
4. WARNING SIGNS
4.1 LABEL INDICATING THE DANGER
5. LIST OF PARTS
3.2 MECHANICAL RISKS
Parts subjected to wear:
• The vanes.
• The bearings.
• The rotor.
These parts should be replaced with original spare parts by
qualified personnel at authorized service centers.
3.3 MACHINE TECHNICAL DATA CHART
Motor constructive features:
Closed self - ventilated two poles motor with IP
55 protection, insulation class F.
Pump constructive features:
Pump body: G 25 CAST IRON
Motor rest: G 25 CAST IRON
Impeller: SINTERED IRON
Motor shaft: INOX STEEL
3.4 FLOW METER CALIBRATION
Calibration is required when the meter is new, after disassembly,
when metering a different fluid, or after significant wear.
A proving container or a container of KNOWN volume will be
needed for the calibration procedure. It is recommended that the
container volume be at least 19 litres (5 gallons).
Procedure for calibration
1. Fill container to a know volume.
2. If indicated amount on the flow meter does not match know vol-
ume, calibration is required. Insure pump power is off and sys-
BEWARE
IT IS FORBIDDEN TO CARRY OUT ANY JOB ON
ELECTRICAL EQUIPMENTS THAT ARE ON VOLTAGE
ANY DEPARTURE FROM INSTRUCTIONS, MUST BE AUTHORIZED
BY THE PERSON IN CHARGE
IN CASE OF UNUSUAL DANGER, ANOTHER PERSON MUST BE PRESENT
IN PLACE AS WELL AS WHO IS CARRYING OUT THE JOB
START WORKING IN ACCORDANCE WITH
THE PRECAUTIONARY MEASURES, ONLY!
In compliance with DPR.547 connected with the prevention of accidents
4
ADAM PUMPS
• PA1 60 • PA2 80-100 L • LIGHTPUMP 60-80-100 L • DRUM TECH 60-80-100 L • HI-TECH 60-80-100 L
5.1 ELECTRIC PUMP PA1 60
M
O
T
O
R
1
1
5
V
POS.
DESCRIPTION
REFERENCE
QTY
230 Volts
115 Volts
1
STATOR MEC 71
64100000000
71009025
1
2
JUNCTION BOX SEAL 63/71-2
10501000000
1
3
CAPACITOR HOLDER Ø10
140250100000
1
4
SCREW Ø 3,5 X 13
80801215000
10
5
CABLE FITTING
140250300000
1
6
SPACER WASHER Ø4
80301400000
1
7
SCREW M4 X 8
82301410100
1
8
SWITCH 22 X 30
190050210000
1
9
SPADE CONNECTOR COVER 6,3
190110000000
6
10
JUNCTION BOX SEAL FKL 71
10502000000
1
11
BEARING 6202 2RS
101001700000
1
12
BEARING 6204 2RS
101001880000
1
13
SHAFT ROTOR MEC 71
62901700000
1
14
SPRING WASHER Ø32
84505000000
1
15
FAN FLANGE MEC 71
15502600000X
1
16
HOUSING BOLT M5 X 125
6100450000Z
4
17
FAN MEC 71 WITH METAL RING Ø14 140260400000
1
18
FAN COVER MEC 71
140260500000
1
19
SHAFT KEY 6 X 6 X 20
90505050000
1
20
CAPACITOR
190061000000
1
21
ELECTRIC BLACK CABLE
190200000000
190000190000
1
22
BY-PASS VALVE
71000520
71000520
1
23
PUMP HOUSING 80 LT 1”/ 1”
71000060
71000060
1
24
BY-PASS SPRING
16001005
16001005
1
25
BY-PASS CAP
71000521
71000521
1
26
O-RING 3118
18001008
18001008
1
27
METAL CAP 1”
17001094
17001094
1
28
BIG PUMP FILTER
41410000
41410000
1
29
“FILTER” STICKER
71000587
71000587
1
30
“CLEAN FILTER” STICKER
71000546
71000546
1
31
O-RING 85 X 3
18001022
18001022
1
32
ROTARY SEAL 20307
12001015020
12001015020
1
33
PUMP ROTOR Ø72
61000010
61000010
1
34
VANE
71000569
71000569
7
35
PUMP COVER
71000063
71000063
1
36
SCREW M5 X 16
13001007
13001007
4
37
PLASTIC CAP Ø31
163013500000
163013500000
2
38
“DANGER” STICKER
71000653
71000653
1
39
“CE” STICKER
220000000000
220000000000
1
5.2 ELECTRIC PUMP PA2 80
M
O
T
O
R
1
1
5
V
tem pressure relieved, then remove seal screw and turn calibra-
tion screw counter clockwise to reduce indicated amount or
clockwise to increase the amount. A full turn will change the indi-
cated amount by approximately 0.4L. Re-install seal screw.
3. Repeat step 2 until calibration is acceptable.
calibration procedure
Summary of Contents for PA1 60
Page 2: ...NOTE...