POS.   DESCRIPTION 

REFERENCE 

 

QTY

 

 

230 Volts 

115 Volts 

MOTOR MEC80 

71009018 

71009019 

1

ELECTRIC BLACK CABLE  

190200000000 

190000190000 

1

BY-PASS VALVE 

71000520 

71000520 

1

BY-PASS SPRING 

16001005 

16001005 

1

BY-PASS CAP 

71000521 

71000521 

1

BIG PUMP FILTER 

41410000 

41410000 

1

O-RING 3118 

18001008 

18001008 

1

METAL CAP 1”  

17001094 

17001094 

1

“FILTER” STICKER 

71000587 

71000587 

1

10 

“CLEAN FILTER” STICKER 

71000546 

71000546 

1

11 

ROTARY SEAL 20307 

12001015020 

12001015020 

1

12 

PUMP ROTOR Ø72 

61000010 

61000010 

1

13 

VANE 

71000569 

71000569 

7

14 

O-RING 85 X 3 

18001022 

18001022 

1

15 

PUMP COVER  

71000063 

71000063 

1

16 

SCREW M5 X 16 

13001007 

13001007 

4

17 

“DANGER” STICKER 

71000653 

71000653  

1

18 

“CE” STICKER 

220000000000 

220000000000  

1

19 

PLASTIC CAP Ø31 

163013500000 

163013500000 

2

20 

FOOT FOR MOTOR MEC80 

240023MEC80 

240023MEC80 

2

electric pump pa2 100

5.3 ELECTRIC PUMP PA2 100

Summary of Contents for PA1 60

Page 1: ...60 PA2 80 100 L LIGHTPUMP 60 80 100 L DRUM TECH 60 80 100 L HI TECH 60 80 100 L ELECTRICPUMP LIGHTPUMP DRUM TECH HI TECH cabinets meter DC and AC pumps accessories repair kit USE AND MAINTENANCE MANU...

Page 2: ...NOTE...

Page 3: ...AM PUMPS Spa Via della Resistenza 48 41011 Campogalliano Modena Italy 2006 NOV Code 21075000000000 ELETTR PA 1 60 230 Volt 50 Hz imb Serial Number 180387 230 Volt 50 Hz IP 55 370W 2 5 A 2800 rpm Conde...

Page 4: ...xtinguishing powders charged with CO2 only Extinguishers should be kept near the pump Combustion of paints and plastic parts may produce toxic emissions use the normal precautions in case of fire alwa...

Page 5: ...ackage for damage and verify that the unit is not damaged Damage must be reported within 10 days of receiving the unit For correct unpacking carefully follow these instructions 1 Placed the case on th...

Page 6: ...he container volume be at least 19 litres 5 gallons Procedure for calibration 1 Fill container to a know volume 2 If indicated amount on the flow meter does not match know vol ume calibration is requi...

Page 7: ...0 41410000 1 7 O RING 3118 18001008 18001008 1 8 METAL CAP 1 17001094 17001094 1 9 FILTER STICKER 71000587 71000587 1 10 CLEAN FILTER STICKER 71000546 71000546 1 11 ROTARY SEAL 20307 12001015020 12001...

Page 8: ...ling service and dispose in the correct manner This will allow the recycling of raw materials and help protect the environment 6 ADAM PUMPS PA1 60 PA2 80 100 L LIGHTPUMP 60 80 100 L DRUM TECH 60 80 10...

Reviews: