© Adam Equipment Company 2008
13
Or, “
SPA
n
” “
FA
i
L
”
This means calibration has failed. Remove
the calibration weight and repeat the
process.
“
JP O
n
”
This is shown only if a jumper was used to
gain access. Switch off the scale. Remove
the jumper. Switch on the scale for normal
weighing.
8.2 USING “2006” TO ENTER THE SERVICE PARAMETERS
After the jumper has been placed at J1 on pins 1 &2, apply power to the scale or use the
Calibration Count method as described in section 7.3 to access the passcode display if the
Counting method has been enabled.
Display will ask for a code number, “
Pn
“ on the Unit Price window.
Enter the number 2006 when “
Pn
“ is displayed and then press
[Tare].
The displays will show the first parameters, called “
F1
” “
CAL
”. To select another parameter
press the
[0]
key to advance through the parameters.
Press the
[Tare]
key to enter a parameter.
To exit a parameter, press the
[
Z
]
key.
The Weight Display window will show the parameter number and the Unit Price window
will show the word describing the function.
When a parameter is entered by pressing the
[Tare]
key, the displays will guide you
through the parameter selected and the options available.
The parameters available are:
F1
CAL
To enter the Calibration
F2
100g
Enable price per 100g or per kg option
F3
Unit
Select kilograms or pounds
F4
CAPA
Select capacity
F5
Point
Unit Price/Price decimal point