background image

 

 

 

© Adam Equipment Company 2020 

 

15 

 

10.0  SERVICE INFORMATION  

  
This manual covers the details of operation. If you have a problem with the scale that is not 

directly addressed by this manual then contact your supplier for assistance. The supplier will 
need the following information which should be kept ready: 

A. 

Details of your company

      

-Name of your company:  
 -Contact person’s name: 
-Contact telephone, e-mail,       fax or anyother methods:  
  

B. 

Details of the unit purchased

   

(This part of information should always be available for any future correspondence. We suggest you to fill 

in this form as soon as the unit is received and keep a print-out in your record for ready reference.)  

             

Model name of the scale: 

 

 

 

  

Serial number of the unit: 

 

 

 

  

Software revision number  

 

(Displayed when power is first turned on): 

 

  

 

 

Date of Purchase: 

 

  

 

 

Name of the supplier and place: 

 

  

          

C. 

Brief description of the problem 

 

Include any recent history of the unit. For example:         

-Has it been working since it’s delivered  
-Has it been in contact with water  
-Damaged from a fire  
-Electrical Storms in the area   
-Dropped on the floor, etc.   

 

 
 

 

Summary of Contents for CKT 16

Page 1: ...ials and environmentally friendly packaging where possible As part of this initiative we have developed a short form manual that uses less paper and ink to describe the main functions of your new Adam...

Page 2: ...am Equipment Company 2020 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and pl...

Page 3: ...SCALE 6 4 2 SCALE COMPONENTS 7 5 0 REPLACING THE LOAD CELL 8 6 0 REPLACING THE DISPLAY 8 6 1 MODULE OPTION COVERS BOARDS 9 7 0 REPLACING THE PCB 9 8 0 CALIBRATION LINEARITY SETTINGS 10 9 0 FACTORY PA...

Page 4: ...gram or kilogram weighing units The scales have stainless steel weighing platforms on an ABS base assembly All scales are supplied with an RS 232 bi directional interface and real time clock The scale...

Page 5: ...g Readability 0 1 g 0 1 g 0 2 g 0 5 g 1 g 2 g Repeatability S D 0 2 g 0 2 g 0 4 g 1 g 2 g 42 g Linearity 0 3 g 0 3 g 0 6 g 1 5 g 3 g 6 g CKT UH Series CKT 8UH CKT 16UH CKT 32UH CKT 48UH Kilograms Maxi...

Page 6: ...D 0 02 oz 0 02 oz 0 02 oz 0 02 oz Linearity 0 06 oz 0 06 oz 0 06 oz 0 06 oz Tare range 16 _16 00 35 _16 0 70 _16 0 100 _16 0 OTHER SPECIFICATIONS Units of measure CKT Series kg g CKTa Series kg g lb o...

Page 7: ...g Scales Functions Weighing Parts counting weighing Check weighing Check counting Accumulation of weights Date Time Real Time Clock RTC To print date and time information battery backed CKT 4M CKT 8M...

Page 8: ...7 digits LCD digital display with symbols for units Scale Housing ABS Plastic Stainless Steel platform Pan Size 225 x 275 mm 8 9 x 10 8 Overall Dimensions wxdxh 315 x 355 x 110 mm 12 4 x 14 x 4 3 Net...

Page 9: ...nector located on the base to the left of the scale 4 Plug the power cable into the mains 5 Press the power button located on scale keypad 6 The scale will then display the software revision and run a...

Page 10: ...requires verification once opened 4 2 SCALE COMPONENTS 1 PCB 2 Keypad 3 Display 4 Spirit level 5 Load cell metal frame upper supporter 6 Load cell 7 Load cell metal frame lower supporter 8 Power cable...

Page 11: ...he screw positions line up Screw in the 2 central screw points to hold the load cell in place then carefully screw in the 4 exterior screw points Once secure place the scale s exterior casing back ont...

Page 12: ...w the plastic cover for the charging board and USB components located beneath the scale Remove the USB and charging component On the inside of the scale disconnect the battery display and power connec...

Page 13: ...Entering the correct password will bring you to the setup menu Once in the setting menu use the directional keys 1 and 6 to scroll through the menu until L Cal appears on the display and press the Tar...

Page 14: ...ider variety of settings and options such as language currency decimal and linear calibration settings The display will show the first parameter ADCnt To scroll through other parameters press the nume...

Page 15: ...te between the options and press Tare to select 9 6 G1 and G2 These options are related to specific gravity parameters of the scale G1 is the gravitational acceleration at place of manufacture G2 is g...

Page 16: ...press Tare to select Note Trade approved machines require this to be set in accordance with specific rules 9 10 AUTO ZERO TRACKING The auto zero function calculates the limits at which the scale can...

Page 17: ...press Tare to select 9 13 DUAL The dual parameter concerns the scale s dual weighing interval and range settings To enter this parameter press the Tare key when Dual is shown Use the numeric 1 or 6 ke...

Page 18: ...s of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in yo...

Page 19: ...ce faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable ba...

Page 20: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this...

Page 21: ...rmany Phone 49 0 4340 40300 0 Fax 49 0 4340 40300 20 e mail vertrieb aeadam de Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 1...

Page 22: ...Adam Equipment Company 2020 19...

Reviews: