2. Under no circumstances should you close the lid while the oil is heating. Never heat 
oil alone! 
3. Do not fill the chamber with oil until the chamber is thoroughly drained and before 
checking that the drain valve has not retained water. Always remember to place an oil 
container under the drain valve. If the valve is not closed, the oil will fall out into the 
tank. 
4. The fryer must not be put into operation after the electric system has been 
punctured. 
5. Remember to wash the inside of the safety valve weight housing and their threaded 
ends daily after finishing frying. 
6. Observe the safety rules and basic health and safety regulations. 
7. When operating the device, remember that the temperature of the device's 
components may be high. Particular care should be taken because the top of the 
appliance reaches a high temperature, which may result in burns. 
 
The manufacturer disclaims any liability for any damage that may be caused to persons 
or objects as a result of failure to comply with the obligations imposed by safety 
regulations and regulations regarding the installation of equipment.

 

 
 
 

 

This device is marked in accordance with the European Directive 2012/19 / EU and the Polish Act of 11 
September 2015. "On used electronic and electronic equipment" (Journal of Laws of 23.10.2015 item 
11688) with a crossed out waste container . Such marking informs that this equipment, after the period 
of its use, may not be placed together with other household waste. The user is obliged to give it to the 
collectors  of  used  electrical  and  electronic  equipment.  Collectors,  including  local  collection  points, 
shops  and  communal  units,  create  an  appropriate  system  enabling  the  delivery  of  this  equipment. 
Proper  handling  of  used  electronic  and  electrical  equipment  contributes  to  avoiding  consequences 
harmful to human health and the environment, resulting from the presence of hazardous components 
and improper storage and processing of such equipment. 
At the end of the life of the equipment, return the device to the appropriate institution that deals with 
the disposal of the devices. On behalf of the manufacturer, the contract regarding the organization and 
provision  of  collection,  processing,  followed  by  recovery  and  recycling  and  disposal  of  "Waste 
Equipment" shall be completed by: 
Elektro-EKO 
Electrical and Electronic Equipment Recovery Organization S.A. 
ul. Łopuszańska95, Warsaw 
ENVIRONMENTAL  PROTECTION:  Both  the  packaging  of  the  new  device  and  the  old,  used  devices 
contain valuable secondary raw materials and materials for recycling. Please dispose of individual parts 
by  type  of  material.  Please  inform  your  dealer  or  local  administration  about  the  current  disposal 
method. 

Summary of Contents for ADA SCE 12

Page 1: ...R I N G A P P L I A N C E S A N D I N O X F U R N I T U R E OPERATING MANUAL Electric Pressure Fryer v 2 02 ADA SCE 12 Maszyny i Urz dzenia Gastronomiczne ADA GASTROGAZ ul Kolejowa 9 66 10 Sulech w P...

Page 2: ...f the users Electric pressure fryer assures short time frying of meat product in hot oil without penetrating the oil into product what gives excellent taste and wholesome values Before you start opera...

Page 3: ...r the safe use of the appliance 16 4 7 First aid 17 4 8 Warnings 17 5 Conditions of the guarantee certificate 19 Guarante Certificate 20 PRECAUTIONS FOR PURCHASERS AND USERS Before starting to operate...

Page 4: ...pecial coating but they can be prepared without it as well You can also use the fryer to prepare toasts doughnuts chips etc In this type of pressure devices you receive the final product crisp crunchy...

Page 5: ...rical installation The heaters heat the frying chamber The thermostat sensor and safety sensor temperature limiter are mounted which turns off the heaters when the oil reaches a temperature of 220 C A...

Page 6: ...s done let the oil out of the chamber using the chamber emptying valve 14 The used oil should be poured through a linen filter in order to purify it and separate the remnants of a meal from it The pur...

Page 7: ...stallation of electrical devices Normy przepisy zarz dzenia dotycz ce wentylacji The appliance installer should Have a qualification certificate Read the information on the type plate Check the effect...

Page 8: ...ppliance to the electric installation it is mandatory to connect a protective conductor with yellow green insulation and a cross section of not less than 2 5 mm to the housing The protective terminal...

Page 9: ...urnontheappliancetoavoiddanger Contactaservice centerandorderrepair After completing the installation of the device the packaging components must not be kept within the reach of children as they may c...

Page 10: ...starting the first frying process wash the frying chamber and the rest of the elements which may contact with food with hot water and suitable detergents Close the chamber drain valve Fill the chamber...

Page 11: ...ched During heating mix the oil several times to avoid uneven heating of the oil This operation should always be carried out when the oil has cooled to ambient temperature Warning Under no circumstanc...

Page 12: ...of the cycle when the pressure gauge reads zero the cover should be lifted up quickly and vigorously but avoiding hitting the hinge bumper To remove fried products put a specially prepared handle on t...

Page 13: ...r and change the oil 5 During the first morning warm up warm the device up by gradually mixing the oil to avoid burning it 6 Remember that every device used in the food industry requires proper care a...

Page 14: ...tank designated for this while standing 5 After draining the fat completely clean the inside of the chamber thoroughly with a brush Carefully remove any accumulated coating particles 6 Flush the chamb...

Page 15: ...serious injury and or burns or material damage 4 4 Additional maintenance performed periodically Check screw connections as well as tightness of oil and condensate valves and pipelines on a regular ba...

Page 16: ...f its proper installation operation and maintenance The basic condition for good operation of the device is to keep it properly clean and to follow the instructions in this instruction manual Before i...

Page 17: ...qualifications and equipment with the required control equipment 4 7 First aid When providing first aid you should call the appropriate medical services facilitate breathing by removing clothing If n...

Page 18: ...nd electronic equipment Journal of Laws of 23 10 2015 item 11688 with a crossed out waste container Such marking informs that this equipment after the period of its use may not be placed together with...

Page 19: ...ome parts in gas appliances light bulb thermocouple burner protection grid ceramic plate glass gasket in electrical equipment light bulb glass gasket 5 In the event of any faulty operation of the devi...

Page 20: ...lectric pressure fryer ADA SCE 12 Fabric number Manufacturing date Manufacturer quality control sign Date of sale Sign and stamp of seler No The date of the declared complaint The date of the repair T...

Reviews: