CHECKS BEFORE STARTING UP
•
Check that the safety valves (DHW and primary) are correctly installed and that the out-
lets are connected to the sewer.
• Check that the DHW tank and the primary circuit are filled with water.
• Check that the air has been correctly bled from both circuits.
• Check that the tank’s upper air bleed valve is tight.
• Check that the water side and heat source side pipes are correctly connected and not
leaking.
STARTING UP
To put the installation into service, refer to the heating boiler manual.
Smart SL-SLEW
: A1007850 - 661Y1700 • F - draft
Starting Up
STARTING UP PROCEDURE
If the SLEW tank is used as an electric DHW tank only :
1. Put the electric plug into the mains socket
2. Set the Summer / Winter switch on the summer (
R
) position and check that
the indicator is on.
3. Adjust the required temperature using the control thermostat.
If the SMART tank is used within a heating system:
To put the heating system into service, refer to the heating boiler manual.
1. Put the Summer / Winter switch on the winter (
T
) position and check that the
indicator is off.
2. Adjust the required temperature using the control thermostat.
31