Heating System Pressure
From time to time you may need to top up the heating circuit
water level to get the required pressure in the system. The
circuit pressure is indicated by the combined temperature
and pressure gauge on the boiler control panel.
The minimum pressure when the boiler is cold should be 1
bar. The precise operating pressure required depends on the
height of the building and your installer will have informed
you of this value at the time of installation (see Starting up
section - Filling the DHW and heating circuits).
If the pressure falls below 1 bar, the boiler water pressure
switch will turn the boiler off until the pressure is restored
To restore the pressure, top up the heating circuit with water
by opening the filling valve (A) of the boiler primary circuit
and allow the system to fill. Once the pressure gauge of the
boiler control panel indicates the required pressure, close the
filling valve.
Safety valves
If water discharges from any of the safety valves, turn the boiler off and
call a service engineer.
BURNER SAFETY MECHANISM
SAFETY CUTOUT OF THE OIL OR GAS BURNER
• HeatMaster® 30 N
The safety cutout indicator is located on the burner and on the
control panel.
The red warning light indicates an operating fault.
Wait 5 min before resetting the burner. To reset: press the button
located on the burner.
If the burner does not restart, call a service engineer after ensuring the
fault is not due to a power failure or low oil level in the tank.
USER'S GUIDE
BURNER TROUBLESHOOTING
For all burners, please refer to the relevant servicing and troubleshooting
instructions in the technical manual of your burner.
A
I
O
RESETTING THE BG 2000 AIR/GAS
PREMIX BURNER
•
HeatMaster® 30 N with BG 2000-S/35
•
HeatMaster® 60 N with BG 2000-S/60
•
HeatMaster® 70 N with BG 2000-S/70
•
HeatMaster® 100 N with BG 2000-S/100
The safety cutout indicator is located on the burner and on the
control panel.
1. Remove the burner cover.
2. Press the red button to restart the burner.
3. If the burner works properly, reinstall the cover.
4. If the the fault persists, call a service engineer.
Summary of Contents for HeatMaster 100 N
Page 16: ...EN FR RU PL DE IT ES NL EN 15 664Y5400 B INSTALLATION 2 x 1 2 3 4 5 6...
Page 21: ...EN FR RU PL DE IT ES NL EN 20 664Y5400 B...
Page 22: ...EN FR RU PL DE IT ES NL EN 21 664Y5400 B...
Page 23: ...EN FR RU PL DE IT ES NL EN 22 664Y5400 B...
Page 24: ...EN FR RU PL DE IT ES NL EN 23 664Y5400 B...
Page 25: ......
Page 26: ......
Page 27: ......