EN • 17
664Y4600 • D
E
N
FR
R
U
P
L
DE
IT
ES
N
L
user GuIde
SAfETY VALVE (CENTRAL HEATING)
A monthly inspection is recommended:
Lift the lever on the emptying device for a few seconds to ensure that
the safety valve is working properly
The water which may flow out of the safety valve
is very hot and may cause serious burns.
The pipe discharging into the waste water disposal
system should be open to the atmosphere.
Make sure there is nobody near the flow of hot
water.
If you notice anything unusual after this short trial,
please inform the installing engineer.
SAfETY uNIT (DOMESTIC HOT wATER)
A monthly inspection is recommended:
Lift the lever on the emptying device for a few seconds to ensure that
the safety valve is working properly.
The water flowing out of the safety unit may be
extremely hot.
The pipe discharging into the waste water disposal
system should be open to the atmosphere.
Make sure there is nobody near the flow of hot
water.
If you notice anything unusual after this short trial,
please inform the installing engineer.
BOILER SHuTDOwN
If the red light on the control panel lights up, this indicates an
operating fault.
1. Check the boiler pressure, it should be between 1 and 2 bar
depending on the height of the building.
2. Once you have checked the pressure, wait until the boiler has
cooled down before resetting the safety thermostat.
3. Unscrew the safety thermostat’s protective cap.
4. Restart the thermostat using a blade end.
5. If the system shuts down again, please inform the installing
engineer.
To ensure your system operates properly, have it
professionally serviced once a year before the cold
weather starts.
BOILER ROOM
• Keep vents free at all times.
• Do not store any inflammable products in the boiler room.
• Take care not to store any corrosive products, such as paints,
solvents, chlorine, salt, soap and other cleaning products, near the
boiler.