![Acute TravelLogic Manual Download Page 36](http://html1.mh-extra.com/html/acute/travellogic/travellogic_manual_2845331036.webp)
36
Acute Technology Inc.
Copyright
2018
3.
The area to set the trigger condition for each class.
4.
OR IF
is the condition for establishing a parallel trigger. At this point, each set of
trigger conditions are judging the conditions at the same time. It is triggered when any
set of conditions is met.
5.
Sequence by
The user can also set incidental conditions for triggering. In general, the data taken at
the sampling point are used for trigger settings. If you want the specified channel at the
changing edge to be triggered only, you should use the “Sequence by” setting. With
such a function, the user does not have to set trigger conditions for each change at the
edge, but just focus on the data to be set.
For example, the signal data to be measured is valid only when the clock is at the rising
edge. There are four data lines. In this case, you can set the Sequence by as Custom
Rising, and then select the Clock pin as the valid condition for the data. Then, you can
set the conditions for other data lines in accordance with Multi Level triggering
conditions.
This function is not supported when the sampling frequency is above 2 GHz (inclusive).
Width Trigger
The width trigger can set the trigger signal when the channel meets the trigger conditions
and the length of the full pulse width.