Acute Technology Inc.
Copyright
2018
Mode 3 Protocol Monitor
Functional description:
Data will be kept in the device and overwrote the old data without returning to the PC,
the capture can be stopped by user manually or by trigger condition matched, then the
device will fill the device memory until memory full and return to PC for display.
Rule:
1.
During the capture period, data are not returned to the PC, reducing the
performance requirements on the USB and the computer.
2.
The total amount of data is the total amount of device memory.
3.
Trigger conditions can be set and monitored for a long time
.
Device
memory will be filled only when the amount of data matches the trigger
conditions.
Notice for use:
1.
If the trigger is not set or you have set the trigger but want to retrieve the
data before the memory is full, you must manually press “Stop” to send
data back to the computer.
Work options
Maximum Device memory limit