  Once  the  ignition  wire  is  detected  take  the  green  color  wire  coming  from  the 

ACUTE140 device and connect it to the ignition wire. Turn on the ignition and ensure 
that ignition is connected properly. 

 
 
 
 
 

10.4

 

Panic button installation 

 

  The panic button has to connect to the DIN2 of the device, so when the panic button 

is pressed the emergency alert is triggered. Below are the connections for the panic 
button installation. 

  During installation the red colour wire of panic will go for power and black will go for 

Digital output of the device. 

  The  green  colour  of  the  panic  will  be  connected  to  the  digital  input  of  the  device 

(Purple  colour)  and  the  yellow  colour  wire  will  be  connected  to  the  ground.  If  the 
number of panic buttons are more than one then the yellow colour will be connected 
to the green colour of the next panic button. 

  The panic button has to connect before turning on the device. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 140

Page 1: ...Acute Communication Services Pvt Ltd User Manual ACUTE 140_______________________________ Quality Never Compromised...

Page 2: ...utton 5 7 Configuration Troubleshooting Commands 6 8 Basic Troubleshooting 7 8 1 Troubleshooting Steps 7 9 Device Installation Precautions 8 10 Installation Procedure 9 10 1 Power Connection in Commer...

Page 3: ...the location of remote asset It is important to mention that ACUTE140 has Digital Analog inputs outputs and a serial communication feature which will control and monitor other devices status on remote...

Page 4: ...Acute Communication Services Pvt Ltd 5 Connector 16 Pin wire harness Diagram Table 1 Connector Pin Table 2 Connector Pin out...

Page 5: ...mary Server IP for sending data usage PIP IP Domain e g password set PIP gpssoftware in or password set PIP 103 135 36 169 2 PPT Primary Port To set Primary Server Port usage PPT Port Number e g passw...

Page 6: ...log 2 Value 9 NWINFO To get current Network Status of the Device Response Format IM IMEI Number OP Operator Name GSM Signal Strength CREG CGREG APN Current APN CON Primary CON Secondary CON Emergency...

Page 7: ...imary Secondary Storage 17 REBOOT Reboot Device To reboot device using SET command Can be sent at the end of all commands Device will reboot automatically after 10 Sec 8 Basic trouble shooting problem...

Page 8: ...metal surrounding the device 5 Check if any metal or item kept on the device and clear the same If Processor LED is OFF 1 Contact Acute Communication Customer Care 9 Device installation Precautions It...

Page 9: ...ice can be installed inside the dash board 10 2 Power Connection Personal Vehicles Remove the Ignition Key Identify the power line Positive cable coming from the battery to the ignition switch by meas...

Page 10: ...ter to the GND terminal of the vehicle battery or any screw Bolt directly connected to metal body of the vehicle and measure the voltage The voltage must be ZERO when the Ignition is in OFF position K...

Page 11: ...e emergency alert is triggered Below are the connections for the panic button installation During installation the red colour wire of panic will go for power and black will go for Digital output of th...

Page 12: ...Acute Communication Services Pvt Ltd 10 5 Device Placement in Vehicles Device placement location in Car Heavy vehicles...

Page 13: ...Acute Communication Services Pvt Ltd 11 FAQ Frequently Asked Questions 1 How do I contact customer support Customer support can be reached via email support acutecommunication in or 91 9119118774 End...

Reviews: