![Acuity AR100 -50 User Manual Download Page 20](http://html1.mh-extra.com/html/acuity/ar100-50/ar100-50_user-manual_2844430020.webp)
14
AR100 Operation Manual
4.5
Logic Outputs (Pink, Grey)
The Pink wire is a multi-purpose logic output / interface that can operate
in eight distinct modes. The functionality can be configured according to
the instructions in section 7 . Functions include distance alarms, multi-
sensor synchronization, setting of Zero Point via hardware control,
encoder input, and control of the laser ON / OFF state.
See Alarm Output Operation (section 7) for operation options and details.
The Logic Output is an open collector NPN transistor switch to the Ground
for Signal (Grey). When the Alarm Output is not active, its output will be
high impedance and no current will flow through it. When the Alarm
Output is active (On) it can source up to 100mA of current. The voltage
on the Alarm wire must not exceed 24 VDC.
Distance Alarms
Multi-sensor Synchronization
Zero point set / Laser On / Off
control
Figure 3
Wiring Diagram
for Distance Alarms
Figure 4
Wiring Diagram
for Multi-sensor
synchronization
Figure 5
Wiring Diagram for
Zero point control and Laser
On / Off