Acuity Brands Lithonia Lighting HomeGuard LED HGX LED 2RH 40K 120 MO Installation Instructions Manual Download Page 4

page 4

Figure E 

WALL MOUNT                                       EAVE MOUNT

Knuckle 

1. 

If testing the light during daytime

, set the TIME control to the TEST 

position

 to disable the photosensor and allow light to come on during 

daylight hours. See Fig. C.

2. Set the SENSITIVITY control to maximum setting. 

See Fig. D. 

Note: 

Factory setting is at highest sensitivity. 

3. Aim the MOTION SENSOR HEAD level 

and across the desired 

detection area. See Fig. A.

A

void aiming the control at:

• 

Objects that change temperature rapidly, such as 

heating vents and 

air conditioners.

 These heat sources could cause false triggering.

• 

Areas where 

pets or traffic

 may trigger the control.

• 

Nearby large, light-colored objects 

reflecting light may trigger the 

shut-off feature. Do not point other lights at the sensor.

Align the arrow on the knuckle between the 0-30 degree mark on the 

motion head see Fig. E. 

Adjust the tilt angle 

between 0-30 degree 

depending on your mounting height and desired detection range. Use 

chart in Fig. B as general guide. 

4. Test motion detection 

by walking across your detection area (70ft 

/200°) in a zigzag pattern. See Fig. F. 

Note: 

Walking up to the motion 

detector in a straight line may keep you in between detection regions, and 

your light will not come on. 

red LED indicator light 

in the motion head 

will flash when motion is detected and the lights will come on momentarily. 
Move to different spots in the area to be tested and stop all motion for 

about 10 seconds. The lights should turn off. Start walking again to see 

if motion is detected in the new spot. Repeat the walk test in other spots 

to determine the coverage area. 

Note: 

When testing assure there are no 

other people or animals causing motion in the detection area.

As distance from the sensor increases, it will take more movement to 

be detected. The sensitivity can be adjusted to increase or decrease 

detection if desired. Adjust the sensitivity as needed. Sensitivity set too 

high may cause false triggering. See Fig. D.

5. Once Motion detection in the coverage area is confirmed, 

set the TIME 

control to 1 or 5 minutes time 

for the lights to remain on at night time 

once motion stops.

 

See Fig. G. 

Note: 

Lights remain on as long as there is 

movement within the detection zone. 

SETTING THE MOTION SENSOR

Make sure the wall switch is in ON position (if controlled by a wall 

switch) 

NOTE: 

During daylight all lights are off. 

WRONG

OK

Figure D 

Figure C 

Sensor

Least Sensitive            Most Sensitive

Motion

Motion

Figure F 

Figure G 

Figure A 

Figure B 

MANUAL OVERRIDE

NOTE: 

TIME contol must be set at 1 or 5 to use manual override.

To disable the motion sensor and keep the light continuously on for the 

night, flip the wall switch off for 3 seconds and then back on. 

To reset to Security mode, flip the switch off again for 3 seconds and then 

back on. 

If you leave the light on all night it will automatically turn off at dawn and 

reset to Security mode.

NOTE: 

If you get confused while switching modes, turn the power at 

the breaker or wall switch off for one minute, then back on. After the 

calibration time, the control will be in the Security mode.

3 Seconds  OFF then...

...back on

Summary of Contents for Lithonia Lighting HomeGuard LED HGX LED 2RH 40K 120 MO

Page 1: ...ction Avant de procéder à l installation veuillez lire attentivement ces directives et les conserver pour référence ultérieure Date de l installation _____________ Tout manquement au respect de ces instructions pourrait rendre nulles les garanties Pour une liste complète des conditions générales du produit veuillez vous rendre sur www acuitybrands com Acuity Brands Lighting Inc n assume aucune res...

Page 2: ... deem otherwise Never connect an LED product directly to a dimmer packs occupancy sensor timing device or other related control devices LED fixtures must be powered directly off a switched circuit Unless individual product specifications deem otherwise Do not restrict fixture ventilation Allow for some volume of airspace around the fixture Avoid covering LED fixtures with insulation foam or other ...

Page 3: ...ounting screw E and remove the mounting bracket Note Center mounting screw and bracket are pre installed on the light fixture for shipping Install the mounting bracket D to the junction box using two 3 4 6 or 8 or 10 mounting screws F Note Choose one of the 3 screw sizes provided depending on your junction box FIXTURE INSTALLATION Position light fixture over j box and align center mounting screw w...

Page 4: ... should turn off Start walking again to see if motion is detected in the new spot Repeat the walk test in other spots to determine the coverage area Note When testing assure there are no other people or animals causing motion in the detection area As distance from the sensor increases it will take more movement to be detected The sensitivity can be adjusted to increase or decrease detection if des...

Page 5: ...e sensitivity Lights flash on and off strobing 1 Heat or light from the lamps may be turning the light control on and off 2 Heat being reflected from other objects may be affecting the sensor 3 Sensor is in Test mode 1 Reposition the lamp heads so Light is not reflected toward the Daylight sensor within the Motion sensor head 2 Reduce Sensitivity 3 While in TEST mode light only stays on for 5 seco...

Page 6: ...el montaje Evite cubrir los montajes LED con aislación goma u otro material que evitará la convección o el enfriamiento de la conducción A menos que las especificaciones del producto individual consideren lo contrario no supere la temperatura ambiente máxima para el montaje Use el montaje sólo en la ubicación para la que está diseñado Los productos LED son sensibles a la polaridad Asegure la corre...

Page 7: ... de conexiones y fije en el soporte de montaje ajustando el tornillo de montaje E Nota Asegúrese de no pellizcar los cables antes de ajustar Inserte el tapón de goma H en el orificio central para cubrir la cabeza del tornillo de montaje central y lograr un sello de humedad PRECAUCIÓN CABLEADO Asegúrese de que la energía eléctrica esté desconectada Utilice la tuerca para conexión de cables para con...

Page 8: ...uces deben apagarse Comience a caminar otra vez para comprobar si se detecta movimiento en el nuevo lugar Repita esta prueba en otros lugares para determinar el área de cobertura A medida que la distancia desde el sensor aumenta se necesitará que el movimiento sea mayor para que pueda detectarse Si lo desea puede ajustar la sensibilidad para aumentar o reducir la capacidad de detección Ajuste la s...

Page 9: ...l calor y la luz de las lámparas pueden encender y apagar el control de luz 2 Es posible que el calor reflejado por otros objetos esté afectando el sensor 3 El sensor está en modo de Prueba 4 Las luces controladas por el sensor brillan o se reflejan en la fotocélula 1 Coloque nuevamente los cabezales de la lámpara alejados del sensor 2 Reduzca la sensibilidad 3 Mientras está en modo de PRUEBA la l...

Page 10: ... la partie 15 du règlement de la FCC Ces limites ont été établies pour offrir une protection raisonnable contre les interférences nuisibles dans les installations résidentielles Cet appareil génére utilise et peut émettre de l énergie de radio fréquence S il n est pas installé de maniére conforme aux instructions il peut causer des interférence nuisibles aux communications radio Il n est toutefois...

Page 11: ...us de la boîte de jonction et fixez le au support de montage en serrant la vis de montage centrale E Remarque Assurez vous qu aucun fil n est coincé avant de serrer Insérez le bouchon en caoutchouc H dans le trou central pour couvrir la tête de la vis de montage centrale pour l étanchéité à l humidité Rétablissez le courant au niveau de la boîte de fusibles ou du disjoncteur et assurez vous que l ...

Page 12: ...ement est détecté et les lumières s allumeront pendant approximativement 4 secondes Déplacez vous vers un autre emplacement dans cette zone pour la tester et arrêtez tout mouvement pendant environ 10 secondes Les lumières devraient s éteindre Recommencez à marcher pour voir si vos mouvements sont détectés dans ce nouvel emplacement Répétez ce test de marche dans d autres emplacements afin de déter...

Page 13: ...uminaire est raccordé au travers d un gradateur ou d une minuterie 1 2 3 Réduire la sensibilité au mouvement 4 Ne PAS utiliser de gradateur ni de minuterie pour contrôler le luminaire Les lumières restent allumées en permanence 1 Le capteur est en mode de commande manuelle 2 La zone de détection est peut être trop grande 3 Le détecteur peut capter un mouvement en raison d un vent en rafales 1 Suiv...

Reviews: