INSTALLATION INSTRUCTIONS
PREPARE FOR INSTALLATION
Remove fixture components and parts pack.
Check to ensure all parts
are included.
Note:
Account for small parts and destroy packing material,
as these may be hazardous to children.
D
G
A
B
C
E
H
F
FIXTURE PACKING LIST
Part Description
Quantity
A Light Fixture.......................................................................................
1
B
Lamp Head
........................................................................................
2
C Motion Sensor ..................................................................................
1
D Mounting bracket (pre-installed)
.......................................................
1
E 1-1/4” #8 Center Mounting Screw (pre-installed) ..............................
1
F 3/4” #8 & #6 & #10 Mounting Screws* .............................................6
G Wire Nuts* .........................................................................................
3
H Rubber Plug*.....................................................................................
1
*Contained in parts packs
Mounting Hardware Included
Silicone Sealant Required
REQUIRED TOOLS
SELECT MOUNTING LOCATION
For installation to properly installed and grounded UL listed round recessed
or surface mounted weatherproof junction box.
Note:
Suitable for eave mount and wall mount above 4ft (1.2m)
Not suitable for ground mount installation
Do
NOT
use with dimmers or timers or on multiple switch circuits. If
dimmer control or three-way dimmer is present contact a qualified
electrician to remove them and replace with regular electrical switch.
Do
NOT
install on the same circuit with an electric motor (i.e. appliances,
HVAC equipment, washer/dryer, garage door opener, etc.
Do
NOT
install near objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause
false triggering.
Do
NOT
install Nearby large, light-colored objects reflecting light may
trigger the shut-off feature. Do not point other lights at the daylight
sensor.
Turn OFF Power at circuit breaker box
CAUTION:
Do not rely on wall switch alone to turn off power.
INSTALLING MOUNTING BRACKET
•
Loosen the center mounting screw (E) and remove the mounting
bracket.
Note:
Center mounting screw and bracket are pre-installed
on the light fixture for shipping.
•
Install the mounting bracket
(D) to the junction box using two 3/4” #6
or #8 or #10 mounting screws (F).
Note:
Choose one of the 3 screw
sizes provided depending on your junction box.
FIXTURE INSTALLATION
•
Position light fixture over j-box and align center mounting screw
with center hole in mounting bracket, secure by tightening center
mounting screw (E).
Note:
Make sure no wires are pinched before
tightening.
•
Insert rubber plug (H) into center hole to cover the center mounting
screw head and provide moisture seal.
CAUTION: WIRING
Make sure power is turned off. Connect to 120V, power source only.
•
Use wire nut to connect the bare copper or green house supply
ground wire to the green fixture ground wire.
Note:
If house wiring
does not include a ground wire, consult your local electrical code for
approved grounding methods.
For proper connection, place wire nut over wires
and twist clockwise until tight.
•
Use wire nut to connect the white fixture wire to the white (neutral)
house supply wire.
•
Use wire nut to connect the black fixture wire to the black house
supply wire.
MOISTURE SEAL
•
Apply silicone caulking (not included) around perimeter of the fixture
where it contacts the mounting surface to avoid water entry.
Turn on electricity at fuse or circuit breaker box and make sure the wall
switch is on to verify success of installatio
n.
Note:
Light Fixture will not
come on during daylight if Motion Sensor Head is not set to TEST mode.
B
AIM LAMP HEADS
Gently grasp lamp heads (B) and position in desired directions.
CAUTION - Risk of Shock:
Aim lamp heads at least 20
°
down below
horizontal in order to prevent water from accumulating inside lens.
See next pages for MOTION SENSOR SET UP INSTRUCTIONS