Figure 21

Before wiring twistlock plug to the power cord, install the
black rubber protective cover as follows;

1.  Compare cord diameter with ring diameter on

end of cover.  If cord diameter is greater than ring
diameters, cut off flush with next larger diameter
ring.

NOTE:  Under no circumstances cut off more than
three rings.

2.  After cutting off ring, if required, slip power cord

through cover and wire twistlock plug.

3.  Slide rubber cover down over plug.

CUT HERE

GR1147

WARNING

Do not break and make the circuit with the plug and
connector. Use the circuit breaker. Failure to use the
circuit breaker may result in electrical shock.

2.7.2

  Uncoil the 20 ft. control cord.  Rotate the power

unit drum switch to the “REV” position to spool enough
cable from the winch to allow attachment of the winch
cable hook to the clevis.

2.7.3

  Make sure the stringing hook is securely holding

the weight of the ring.  Disconnect the safety cable and
attach the winch cable to the U-shaped bail of the
clevis.  Allow the safety cable hook to hang outside the
pole through the top handhole when not in use.

WARNING

Proceed carefully with the following steps.  The mount-
ing ring is now supported by the stringing hook.  Do not
unhook the stringing hook until the power unit is firmly
installed in the pole.

Do not leave this too long since it can become entangled
with the winch cable.  Reference the wiring diagram
inserted in this manual and install and wire the plug.
Install rubber plug cover if required.  For details of rubber
cover installation, see Figure 21.  The rubber plug cover
is supplied for 30 amp plugs only.

2.7  Lower Ring to Ground for Luminaire Installa-
tion

2.7.1

  For voltages other than 120 volts, connect the

secondary of the transformer to the portable drive
motor.  Plug the cord from the primary of the trans-
former into the circuit breaker cord.  Turn on the circuit
breaker to energize the power unit.  With 120 volt
systems there is no transformer and the portable drive
motor cord plugs directly into the circuit breaker cord.

Supports for Highway Signs,Luminaires and Traffic
Signals - Fifth Edition 2009 Section 5.17.5.2 anchor bolt
pretensioning .

2.6.3

  Reference the wiring diagram inserted at the end

of this section and make the appropriate connections to
the circuit breaker.  Install the circuit breaker cover.

2.6.4

  Be sure the power cord is hanging freely through

the hole in the clevis.  Position the cord clamp approxi-
mately two inches below the clevis plate and tighten the
cord clamp screws securely.  (See Figure 20)

2.6.5

  Cut off the power cord 8 to 10 in. below the clamp.

12

CLEVIS

CORD

PLUG

2” TO 3”

8” TO 10”

Figure 20

GR1146

POWER

Summary of Contents for Holophane 15

Page 1: ...ity Brands Lighting Inc assumes no responsibility for claims arising out of improper or careless installation or handling of its products 2010 Acuity Brands Lighting Inc All rights reserved 6 03 13 AB...

Page 2: ...hane Refer to the manual number in the lower right corner of this page Less detailed information regarding installation operation and main tenance of Holophane Lowering Devices is available in VHS vid...

Page 3: ...ting and maintenance personnel must read and understand completely Sections III and IV 3 Additional copies of this manual are available from Holophane 4 To expedite information and service call 740 34...

Page 4: ...ons Section III Operating Instructions Section IV Maintenance Instructions 4 1 LUBRICATION 4 2 REPLACING THE WINCH CABLE 4 3 PORTABLE DRIVE MOTOR SHAFT REPLACEMENT 4 4 POWER CORD REPLACEMENT 4 5 LUMIN...

Page 5: ...junction box one per Clevis assembly with coiled hoisting cables one per Circuit breaker assembly and enclosure one per Luminaire mounting arms quantity as required Safety cable and stringing hook one...

Page 6: ...GR1129 4...

Page 7: ...2 2 3 Unpack the junction box with the main power cord and place near the top of pole Uncoil the power cord halfway down along the pole and back to the top Uncoil in a manner that will not leave the...

Page 8: ...on the power cable just under the clevis plate The location of the clamp is not critical at this time The clamp will be repositioned after the pole is erected NOTE Double check for crossed or wrapped...

Page 9: ...side the pole Make sure the clevis pin is secured with a cotter pin See Figure 8 The stringing hook keeps the clevis from being pulled back up the pole while rigging the hoisting cables and holds the...

Page 10: ...forced out and may be discarded 2 4 7 Repeat the steps in paragraphs 2 4 4 through 2 4 6 5 for the remaining two cables CAUTION Make sure all the hoisting cables are seated in their respective pulley...

Page 11: ...the ring at the location immediately adjacent and to the right of the power cord slot See Figure 14 2 5 4 Install the junction box onto the left side of the junction box arm using the four 1 4 20 nuts...

Page 12: ...luminaires mount the FAA marker at any vacant luminaire mounting position Counterweight locations Mount counterweight at these locations for lowering devices with 2 3 and 4 luminaires IMPORTANT The co...

Page 13: ...g near the power cord strain plate The rope length must be at least the length of the pole This will be used to apply downward force on the ring in the event that the size and length of the power cord...

Page 14: ...Do not unhook the stringing hook until the power unit is firmly installed in the pole Do not leave this too long since it can become entangled with the winch cable Reference the wiring diagram insert...

Page 15: ...The device complete with luminaires 2 7 4 The portable drive motor can now be used to pull itself into the lower handhole Rotate the switch to the FOR position The tongue of the power unit will be pul...

Page 16: ...uit breaker cord from the portable drive motor or transformer and connect it to the main power cord in the pole 2 8 12 Remove the portable drive motor place the manual in the plastic pouch provided an...

Page 17: ...SINGLE CIRCUIT WIRING DIAGRAMS GR1164 GR1165 GR1166 15...

Page 18: ...DOUBLE CIRCUIT WIRING DIAGRAMS GR1167 GR1168 16...

Page 19: ...BEFORE OPERATING THE DEVICE 3 0 General Comments 3 0 1 The portable drive motor is provided with a twenty foot long remote control cord and switch This permits the operator to stand a safe distance f...

Page 20: ...not break and make the circuit with the plug and connector Use the circuit breaker Failure to use the circuit breaker may result in electrical shock 3 3 1 Turn off the circuit breaker 3 3 2 Disconnect...

Page 21: ...release to OFF as soon as the latch flags rotate perpendicular to the ring See Figure 27 3 4 4 Unwind the winch just enough to remove tension from the winch cable 3 5 Final Steps 3 5 1 Loosen the han...

Page 22: ...then discard the cable 4 2 3 Attach the new cable obtained from Holophane in the same manner that the old cable was attached 4 2 4 While rewinding the winch wrap as tightly and neatly as possible to a...

Page 23: ...ring approxi mately 10 ft while keeping tension on the old cord Then lower the ring and the cord will come down with it HOLOPHANE High Mast Lowering Devices SECTION IV 4 4 13 Disconnect the old cord...

Page 24: ...HOLOPHANE High Mast Lowering Devices SECTION V ATTACHMENTS 22...

Page 25: ...IM 187 E 1 13 2013 Acuity Brands Inc Visit our web site at www holophane com Acuity Lighting Group Inc Field Service Department P O Box3004 Newark OH43058 3004 Printed in USA...

Reviews: