2.5  Completing the Pole-top Assembly

2.5.1

  If the device is equipped with a bumper ring

instead of iris-type guide arms, proceed to paragraph
2.5.3.  Otherwise, attach both guide arm spring brack-
ets to the ring.  (See Figure 13)  The double washers
must be installed between the brackets and the ring to
avoid possible interference with the luminaire mounting
brackets which will be mounted to the ring later.
Tighten each locknut until it is snug and then loosen it
about one half turn to allow the bracket to pivot.

2.5.2

  Adjust the guide arms so the distance between

each wheel and the surface of the pole is 1/4 - 1/2 in.  It
will be necessary to lift the ring to center the wheels
while checking the clearance between the wheels and
the pole.  The adjustment is made by rotating the two
adjustment nuts on the ends of the two spring guide
rods.  Use two wrenches to lock the adjustment nuts in
place by jamming them together tightly.  (See Figure
13)

HOLOPHANE

High Mast
Lowering Devices

SECTION II

2.5.3

  Install the junction box arm on the ring at the

location immediately adjacent and to the right of the
power cord slot.  (See Figure 14)

2.5.4

  Install the junction box onto the left side of the

junction box arm using the four 1/4-20 nuts and
lockwashers supplied in the bag attached to the strain
plate.

CAUTION

Do not attempt to remove the nuts attached to the studs
protruding from the back of the junction box.

Figure 13

WASHERS (2)

ANGLE
BRACKET

ADJUSTMENT
NUTS

RING

LOCKNUT

2.5.5

  Install the power cord strain plate, attached to the

power cord, to the underside of the top flange of the
ring using the 3/8” bolt and locknut supplied.  (See
Figure 15)

GR1142

Figure 15

2.5.6

  Pull the power cord down the pole until tightly

seated onto its rollers.  If the cord extends below the
pole base, it is advisable to move the clamp toward the
clevis plate and then secure the excess cord to protect
it during the pole erection.

2.5.7

  If the optional lightening rod is supplied, find the

dimple located on the top surface of the headframe
cover.  Otherwise, proceed to step 2.5.8.

2.5.7.1

  Punch a 7/8" hole in the cover at the dimple

location and install the rubber grommet.

2.5.7.2

  Thread the lightning rod into the lightning rod

bracket, tightening securely.

Figure 14

GR1224

GR1143

9

Summary of Contents for Holophane 15

Page 1: ...ity Brands Lighting Inc assumes no responsibility for claims arising out of improper or careless installation or handling of its products 2010 Acuity Brands Lighting Inc All rights reserved 6 03 13 AB...

Page 2: ...hane Refer to the manual number in the lower right corner of this page Less detailed information regarding installation operation and main tenance of Holophane Lowering Devices is available in VHS vid...

Page 3: ...ting and maintenance personnel must read and understand completely Sections III and IV 3 Additional copies of this manual are available from Holophane 4 To expedite information and service call 740 34...

Page 4: ...ons Section III Operating Instructions Section IV Maintenance Instructions 4 1 LUBRICATION 4 2 REPLACING THE WINCH CABLE 4 3 PORTABLE DRIVE MOTOR SHAFT REPLACEMENT 4 4 POWER CORD REPLACEMENT 4 5 LUMIN...

Page 5: ...junction box one per Clevis assembly with coiled hoisting cables one per Circuit breaker assembly and enclosure one per Luminaire mounting arms quantity as required Safety cable and stringing hook one...

Page 6: ...GR1129 4...

Page 7: ...2 2 3 Unpack the junction box with the main power cord and place near the top of pole Uncoil the power cord halfway down along the pole and back to the top Uncoil in a manner that will not leave the...

Page 8: ...on the power cable just under the clevis plate The location of the clamp is not critical at this time The clamp will be repositioned after the pole is erected NOTE Double check for crossed or wrapped...

Page 9: ...side the pole Make sure the clevis pin is secured with a cotter pin See Figure 8 The stringing hook keeps the clevis from being pulled back up the pole while rigging the hoisting cables and holds the...

Page 10: ...forced out and may be discarded 2 4 7 Repeat the steps in paragraphs 2 4 4 through 2 4 6 5 for the remaining two cables CAUTION Make sure all the hoisting cables are seated in their respective pulley...

Page 11: ...the ring at the location immediately adjacent and to the right of the power cord slot See Figure 14 2 5 4 Install the junction box onto the left side of the junction box arm using the four 1 4 20 nuts...

Page 12: ...luminaires mount the FAA marker at any vacant luminaire mounting position Counterweight locations Mount counterweight at these locations for lowering devices with 2 3 and 4 luminaires IMPORTANT The co...

Page 13: ...g near the power cord strain plate The rope length must be at least the length of the pole This will be used to apply downward force on the ring in the event that the size and length of the power cord...

Page 14: ...Do not unhook the stringing hook until the power unit is firmly installed in the pole Do not leave this too long since it can become entangled with the winch cable Reference the wiring diagram insert...

Page 15: ...The device complete with luminaires 2 7 4 The portable drive motor can now be used to pull itself into the lower handhole Rotate the switch to the FOR position The tongue of the power unit will be pul...

Page 16: ...uit breaker cord from the portable drive motor or transformer and connect it to the main power cord in the pole 2 8 12 Remove the portable drive motor place the manual in the plastic pouch provided an...

Page 17: ...SINGLE CIRCUIT WIRING DIAGRAMS GR1164 GR1165 GR1166 15...

Page 18: ...DOUBLE CIRCUIT WIRING DIAGRAMS GR1167 GR1168 16...

Page 19: ...BEFORE OPERATING THE DEVICE 3 0 General Comments 3 0 1 The portable drive motor is provided with a twenty foot long remote control cord and switch This permits the operator to stand a safe distance f...

Page 20: ...not break and make the circuit with the plug and connector Use the circuit breaker Failure to use the circuit breaker may result in electrical shock 3 3 1 Turn off the circuit breaker 3 3 2 Disconnect...

Page 21: ...release to OFF as soon as the latch flags rotate perpendicular to the ring See Figure 27 3 4 4 Unwind the winch just enough to remove tension from the winch cable 3 5 Final Steps 3 5 1 Loosen the han...

Page 22: ...then discard the cable 4 2 3 Attach the new cable obtained from Holophane in the same manner that the old cable was attached 4 2 4 While rewinding the winch wrap as tightly and neatly as possible to a...

Page 23: ...ring approxi mately 10 ft while keeping tension on the old cord Then lower the ring and the cord will come down with it HOLOPHANE High Mast Lowering Devices SECTION IV 4 4 13 Disconnect the old cord...

Page 24: ...HOLOPHANE High Mast Lowering Devices SECTION V ATTACHMENTS 22...

Page 25: ...IM 187 E 1 13 2013 Acuity Brands Inc Visit our web site at www holophane com Acuity Lighting Group Inc Field Service Department P O Box3004 Newark OH43058 3004 Printed in USA...

Reviews: