TROUBLESHOOTING
Always use proper precautions and turn off fireplace before performing any maintenance.
Do not clean appliance when hot.
Clean the tempered glass with a basic household glass cleaner every 3 months to 1 year (depending on
frequency of use). Never use abrasive cleaners or glass cleaner that contains ammonia, as it may etch the
tempered glass.
Examination and inspection of the appliance, venting system, and all components including the burner,
should be performed annually by a qualified service technician.
Examination and visual check of the burner & flame should be performed periodically to ensure proper
operation. If the flame deviates greatly from the standard or if any portion of the burner has a large gap
between flames, the burner orifices may need cleaning. Contact a qualified technician to diagnose, correct,
and clean the burner orifices as needed.
Replacement of worn, broken, or non-functioning components should be left to a qualified service techni
-
cian.
If glass panels suffer any type of impact, immediately cease use of fireplace until a qualified technician can
assess the integrity of the panels and determine if they need replacement before continued use.
The area around the appliance must be kept clear and free from combustible materials, gasoline, and other
flammable vapors and liquids.
Keep combustion and ventilation air flows unobstructed.
MAINTENANCE & CARE
DRAFT
Summary of Contents for circular 4
Page 8: ...8 INSTALLATION GUIDE D R A F T...
Page 24: ...SUPPLEMENTAL MATERIAL 24 Gas Valve Ignition Module D R A F T...
Page 25: ...SUPPLEMENTAL MATERIAL 25 Gas Valve Ignition Module D R A F T...
Page 35: ...NOTES D R A F T...
Page 37: ...37 PRODUCT SPECIFICATIONS D R A F T...
Page 38: ...38 PRODUCT SPECIFICATIONS D R A F T...
Page 44: ...44 NOTES D R A F T...