Installation Instructions – Indoor Unit
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the label on the
product box to make sure that the model number of the
indoor unit matches the model number of the outdoor
unit.
Step 1: Select installation location
Before installing the indoor unit, you must choose an
appropriate location. The following are standards that will
help you choose an appropriate location for the unit.
Proper installation locations meet the following
standards:
þ
Good air circulation
þ
Convenient drainage
þ
Noise from the unit will not disturb other people
þ
Firm and solid—the location will not vibrate
þ
Strong enough to support the weight of the unit
þ
A location at least one metre from all other electrical
devices (e.g., TV, radio, computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might block air circulation
Near the doorway
In a location subject to direct sunlight
NOTE ABOUT WALL HOLE:
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should
leave ample room for a wall hole (see
Drill wall hole
for connective piping
step) for the signal cable and
refrigerant piping that connect the indoor and outdoor
units. The default position for all piping is the right side of
the indoor unit (while facing the unit). However, the unit
can accommodate piping to both the left and right.
Refer to the following diagram to ensure proper
distance from walls and ceiling:
5. Indoor Unit Installation
Serene Wall Hung Split System
Installation Overview
150 mm OR MORE
120 mm OR MORE
120 mm OR MORE
2300 mm OR MORE