MINIMUM SERVICE ACCESS AREAS AND AIRFLOW CLEARANCES
NOTES:
1. Do not scale drawing. All dimensions are in mm unless specified.
2. Refer to Field Pipe connection details on specifications sheet.
3. Service Clearances given are suggested minimum based on the
condition that the spaces around the units are free from any
obstructions and a walkway passage of 1000mm between the
units or between the unit and the outside perimeter is available.
4. Minimum service access clearances are responsibilities of the
installer, ActronAir will not be held liable for any extra charges
incurred due to lack of access.
THIRD ANGLE
PROJECTION
EC
ID FAN
EC
ID FAN
INDOOR COIL
HEIGHT CLEARANCE = 410mm
DUCT WORK
DUCT WORK
850 mm
SERVICE
CLEARANCE
850 mm
SERVICE
CLEARANCE
(ELECTRICALS)
RF
LF
LR
RR
UNIT MODEL NUMBER
UNIT WEIGHT
(kg)
SRV191E / SRM191E
76
SRV201E / SRM201E
76
SUPPLY
AIR
715
310
310
1420 O/A
1140
80
120
630
20
20
SAFETY DRAIN TRAY
20 mm ID
CONDENSATE DRAIN
20 mm ID
435
O/A
INDOOR COIL
1375
90
130
SUPPLY AIR
590
40
50
680 O/A
360
50
25
110
300
25
RETURN
AIR
ELECT
BOX &
ACCESS
PANEL
EC
INDOOR
FAN
EC
INDOOR
FAN
LIQUID PIPE
9.5 mm (3/8")
SWAGED
GAS PIPE
22.2 mm (7/8")
CUT SWAGE END
TOP VIEW
FRONT VIEW
SIDE VIEW
OVERALL NOMINAL DIMENSION (H X W X L)
= 435 X 1420 X 680
SUPPLY DUCT (H X W) = 300 X 715
RETURN DUCT = 360 X 1140
CONDENSATE DRAIN CONNECTION = 20mm OD