CAUTION! - To reduce the risk of electric shock, this equipment has a grounding 

type plug that has a third (grounding) pin . This plug will only fit into a grounding 

type power outlet . If the plug does not fit into the outlet, contact qualified 

personnel to install the proper outlet . Do not alter the plug in any way .

WARNING! - Do not operate this unit without one or all purification plate(s) 

properly installed . Doing so may void the warranty .

CAUTION! - Disconnect power cord before servicing . 

100 and 120 volt models - use 1 .6 Amp slow blow fuse .

220 and 240 volt models - use 0 .5 Amp slow blow fuse .

Location for Protective Earth Line .

SPECIFIC

A

TIONS

   

 Features:

•  Positive/Negative Ion Generation Technology .
• Adjustable Ozone Generation .
•  Activated Charcoal Deodorization .
• Adjustable fan speed control .
• Washable permanent lint screen .
•  Adjustable ozone control and plate configuration .
• Adjustable ion control .

 Electrical:

•  100 volt 50/60hz, 120 volt 60hz, 230 volt 50/60 hz, or 240 volt 50 hz .
• Less than 60 watts power consumption .
•  24 to 30 KV, 20-30 khz ion generation pulsator .
• 20 KV negative ion generator .

 Mechanical:

• 82 CFM

 Size:

•  Dimensions: 15 .5” high x 12” wide x 12 .75” deep
• Weight: 35 pounds

 Ozone Output:

•  140-430 mg per hour (depending on the number of plates installed) .

Summary of Contents for EAGLE 5000

Page 1: ...eration Does not meet California requirements cannot be shipped to California OWNER S MANUAL Application Notable Features Specifications Installation Operation Maintenance Warranty EAGLE 5000 ELECTRON...

Page 2: ...number of your Eagle 5000 Serial _____________________________________________________________________ Specifications 3 Introduction 4 Features 4 Applications 4 Installation 5 Lint Screen Carbon Filt...

Page 3: ...blow fuse 220 and 240 volt models use 0 5 Amp slow blow fuse Location for Protective Earth Line S P E C I F I C A T I O N S Features Positive Negative Ion Generation Technology Adjustable Ozone Gener...

Page 4: ...ors It is not designed to create an artificial environment The reestablishment of a natural environment takes place out in the air rather than inside the unit It cleanses the air rather than filtering...

Page 5: ...ge 8 7 Install the rear lint screen bottom of page 8 8 Fully insert cord into the power cord receptacle on the back of the unit 9 Determine placement location for the unit page 9 plug the unit into a...

Page 6: ...nlyonescrewfromeachofthe2topcorner bracketsandrotatebracketoutoftheway 3 3 Remove2screwsfrombottomoflintscreen 4 4 Pulltopoflintscreentowardyou thenliftout 5 5 Oncethelintscreenisremoved thecarbonfilt...

Page 7: ...tingchart beloworonthe faceplateoftheunit todeterminethecorrectnumberofplatesto install 3 Fullyinserttheneededpurificationplates a b c betweentheguide groovesinthesidesoftheplatecage betweenthepostsan...

Page 8: ...inplace insertthetopofthefilterintothecase 3 3 Whenproperly installed thecarbon filterfitsagainsttheinternal stopslocatedontheleftandrightinsidesofthecase Carbon filter stop 1 1 Alwaysinstalllintscree...

Page 9: ...ns and ozone to be mixed evenly and thoroughly with the polluted air Suggested locations listed in the order of preference 1 Nearest the source of the worst pollution 2 Near a cold air return to thoro...

Page 10: ...environment refertopurifierchartonpage7 2 Keeping in mind the previous statement 1 adjust the purifier so that the scent of ozone fades into the background 15 30 seconds after entering the environmen...

Page 11: ...he unit Wash in hot water brushing gently with a toothbrush to remove particulate Allow to dry completely prior to reinstalling the lint screen purification plate Remove the rear lint screen page 6 Ca...

Page 12: ...tches and pulling straight out If the fuse is blown replace with a new slow blow type fuse Insert the new fuse into the fuse holder Press the assembly in until it latches If the fuse holder cap is not...

Page 13: ...completely seated and secured in its receptacle Be sure the cord is fully plugged into unit 2 The fan is operating although the unit won t produce any ozone what s wrong Check the purification plate s...

Page 14: ...accumulation within the environment as a result of improper purifier control setting and or lack of air movement Symptom Visual haze of smoke and or particulate remain within the environment Problem L...

Page 15: ...sites that are not authorized to use activTek s trademarked names images and logos as well as Internet auction sites e g eBay and craigslist The only approved Internet presence for activTek products i...

Page 16: ...IBLE PARTY DBG Group Investments LLC dba activTekEnvironmental 5420 LBJ Freeway Suite 1010 Dallas TX 75240 Ph 800 989 2299 Signature ___________________________ Printed Name Andy Eide Title Vice Presi...

Reviews: