background image

10

1.  FAN CONTROL

The disbursement of cleansing properties is best accomplished with good air circulation . 
The fan control should be set as high as reasonably possible without creating an 
undesirable noise level . This will be determined by personal preference and the distance 
you wish the cleansing properties to be dispersed . 

   Note: A ceiling fan can also aid in distribution of cleansing properties. 

2. PURIFIER CONTROL

PURIFIER Control: Set the control at the nine o'clock position for one hour .

Adjust the control up or down after one hour based on the following criteria:

1 .  In normal conditions, it is not necessary to turn the PURIFIER control indicator above 

the area of the environment . (

refer to purifier chart on page 7

)

2 .  Keeping in mind the previous statement (#1), adjust the purifier so that the scent of 

ozone fades into the background 15-30 seconds after entering the environment .

3.  AWAY MODE FEATURE 

For maximum effectiveness in reducing air contaminants, turn the unit on high for 3-4 
hours .

Air out room by opening doors and/or windows .

4. ION CONTROL

The normal setting of a DC ionizer is full negative .  This 
setting seems to work best in removing particulate 
(cigarette smoke) as well as reducing static .  When 
trying to reduce static, if the full negative setting 
results in more static, turn the ion control in small 
increments towards the positive until the static is 
relieved .

Purifier Control

Fan Control

Ion Control

SETTINGS AND ADJUSTMENTS

Caution: Always be sure a room or area is 

UNOCCUPIED before performing the above 

described Away Mode procedure.

Summary of Contents for EAGLE 5000

Page 1: ...eration Does not meet California requirements cannot be shipped to California OWNER S MANUAL Application Notable Features Specifications Installation Operation Maintenance Warranty EAGLE 5000 ELECTRON...

Page 2: ...number of your Eagle 5000 Serial _____________________________________________________________________ Specifications 3 Introduction 4 Features 4 Applications 4 Installation 5 Lint Screen Carbon Filt...

Page 3: ...blow fuse 220 and 240 volt models use 0 5 Amp slow blow fuse Location for Protective Earth Line S P E C I F I C A T I O N S Features Positive Negative Ion Generation Technology Adjustable Ozone Gener...

Page 4: ...ors It is not designed to create an artificial environment The reestablishment of a natural environment takes place out in the air rather than inside the unit It cleanses the air rather than filtering...

Page 5: ...ge 8 7 Install the rear lint screen bottom of page 8 8 Fully insert cord into the power cord receptacle on the back of the unit 9 Determine placement location for the unit page 9 plug the unit into a...

Page 6: ...nlyonescrewfromeachofthe2topcorner bracketsandrotatebracketoutoftheway 3 3 Remove2screwsfrombottomoflintscreen 4 4 Pulltopoflintscreentowardyou thenliftout 5 5 Oncethelintscreenisremoved thecarbonfilt...

Page 7: ...tingchart beloworonthe faceplateoftheunit todeterminethecorrectnumberofplatesto install 3 Fullyinserttheneededpurificationplates a b c betweentheguide groovesinthesidesoftheplatecage betweenthepostsan...

Page 8: ...inplace insertthetopofthefilterintothecase 3 3 Whenproperly installed thecarbon filterfitsagainsttheinternal stopslocatedontheleftandrightinsidesofthecase Carbon filter stop 1 1 Alwaysinstalllintscree...

Page 9: ...ns and ozone to be mixed evenly and thoroughly with the polluted air Suggested locations listed in the order of preference 1 Nearest the source of the worst pollution 2 Near a cold air return to thoro...

Page 10: ...environment refertopurifierchartonpage7 2 Keeping in mind the previous statement 1 adjust the purifier so that the scent of ozone fades into the background 15 30 seconds after entering the environmen...

Page 11: ...he unit Wash in hot water brushing gently with a toothbrush to remove particulate Allow to dry completely prior to reinstalling the lint screen purification plate Remove the rear lint screen page 6 Ca...

Page 12: ...tches and pulling straight out If the fuse is blown replace with a new slow blow type fuse Insert the new fuse into the fuse holder Press the assembly in until it latches If the fuse holder cap is not...

Page 13: ...completely seated and secured in its receptacle Be sure the cord is fully plugged into unit 2 The fan is operating although the unit won t produce any ozone what s wrong Check the purification plate s...

Page 14: ...accumulation within the environment as a result of improper purifier control setting and or lack of air movement Symptom Visual haze of smoke and or particulate remain within the environment Problem L...

Page 15: ...sites that are not authorized to use activTek s trademarked names images and logos as well as Internet auction sites e g eBay and craigslist The only approved Internet presence for activTek products i...

Page 16: ...IBLE PARTY DBG Group Investments LLC dba activTekEnvironmental 5420 LBJ Freeway Suite 1010 Dallas TX 75240 Ph 800 989 2299 Signature ___________________________ Printed Name Andy Eide Title Vice Presi...

Reviews: