AT-1212 User Guide and Specifications - 25 -
www.activetechnologies.it
3.
Select and open AT1120_1212_SignalGenerator.lvproj LabView project.
4.
In the
Project Explorer
window, open
DACModuleControl (Host).vi
under
My Computer
. The
host VI opens. The Open FPGA VI Reference function in this VI uses the NI 7962R as the FPGA
target by default. If you are using an NI FlexRIO FPGA module other than the NI 7962R, select the
FPGA target by using RIO Device
Menu Ring
.
5.
On the front panel, in the
resource
pull-down menu, select an AT-1212 resource that
corresponds with the target configured in step 4.
6.
Select
1212- 2CHs
in the
Adapter Name
pull-down menu.
7.
Select
AO 0
in the
Selected Channel
pull-down menu.
8.
Select
ARB
in the
DDS-ARB
control
9.
Select
Internal
in the
Clock Selection
pull-down menu and
From Oscillator
in the
Internal
Clock Source
pull-down menu.
10.
Click the Run button to run the VI.
11.
Wait until Module Ready and DAC Aligned leds become green