40
Result Codes:
OK
n = 0, 1, 2, 3
ERROR
Otherwise
\Bn
Transmit Break to Remote
In non-error correction mode, the modem will transmit a break signal to the re-
mote modem with a length in multiples of 100ms according to parameter speci-
fied. The command works in conjunction with the \K command.
\B1-\B9 Break length in 100ms units. (Default = 3.) (Non-error corrected mode
only.)
Result Codes:
OK
If connected in data modem mode.
NO CARRIER If not connected or connected in fax modem mode.
\G
Modem Port Flow Control
\G0: Returns an OK for compatibility (default).
\G1: NOT SUPPORTED responds ERROR.
Result Codes:
OK
n = 0
ERROR
Otherwise
\J
Adjust Bits/s Rate Control
When this feature is enabled, the modem emulates the behavior of modems that
force the DTE interface to the line speed.
\J0: Turn off feature (default).
\J1: Turn on feature.
Result Codes:
OK
n = 0, 1
ERROR
Otherwise
Summary of Contents for DataLink V.90 FM560LKI