background image

ActronAir

 

is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice.

Copyright © 2017 Actron Engineering Pty. Ltd.

Page 13 of  16

MAXIMUM CABLE LENGTHS

 

INTEGRATED ZONE BARRELS 

(1-Zone Up To 8-Zone Options / Max. of 10 Zone Motors per System 

^^

)

MODEL

R-410A

“CAUTION”

PLEASE

THERE IS

NO GAS / PRESSURE IN THE

FAN COIL UNIT BEFORE

REMOVING COPPER END CAPS.

ENSURE

3670-043

Sen

sor

4

CAUTION

LIVE ELECTRICAL WIRING

AUTHORISED TECHNICIANS ONLY

INTERNAL CONTROL ISOLATOR FITTED

MODEL

MEPS

C E R T I F I E D

A

U

S

T

RA

LIAN M

A

D

E

A

U

S

T

RA

L IAN O

W

N

E

D

R-410A

8 ZONE

MODULE

1.5V

AAA

1.5V

AAA

1.5V

AAA

1.5V

AAA

TYPE

10" (250 mm)

PART NUMBER

ZB-10-250

INTEGRATED ZONE BARREL PART NUMBERS

12" (300 mm)

ZB-12-300

Please check prior to purchase.

ActronAir is constantly seeking ways to improve the design of it's products, therefore specifications are subject to change without notice.

ZB-080129

INTEGRATED ZONE BARRELS

12" (300 mm)

10" (250 mm)

16" (400 mm)

14" (350 mm)

14" (350 mm)

16" (400 mm)

ZB-14-350

ZB-16-400

ITEM

PART NUMBER

24 VOLT 4 ZONE KIT

4Z-24V

INCLUSIONS

5 YEAR RESIDENTIAL / 2 YEAR COMMERCIAL
PARTS ONLY WARRANTY

ROBUST METAL BARREL CONSTRUCTION

10 mm FIRE RATED POLYETHELYNE 
INSULATION

7 m CABLE SUPPLIED
(JOINERS AND EXTRA CABLE AVAILABLE)

EASY SNAP-IN WIRING CONNECTION

FAST REACTION TIME

SAFE LOW VOLTAGE (24 VAC)

HIGH TORQUE MOTOR (3 Nm)

DAMPER POSITION INDICATOR

BLADE SEAL INSULATION

FEATURES:

24 VOLT,  3 Nm MOTOR
DRIVE OPEN / DRIVE CLOSE

INSULATED METAL 
ZONE BARREL

7 METER SNAP-IN CABLE

24 VOLT ZONE KIT

NOTE:

THE TOTAL LENGTH OF ALL GREY CABLES CONNECTED
TO THE ZONE MOTORS MUST NOT EXCEED 100 METERS

INCLUSIONS: 4Z-24V (4 ZONE KIT)

NOTE:

WHEN USING INTEGRATED ZONE BARRELS YOU
WILL REQUIRE THE APPLICABLE ZONE KIT. 
(INCLUSIONS & INSTALLATION INSTRUCTIONS 
AS PER DETAILED LIST)

OPTIONAL EXTRAS & SPARE PARTS

INTEGRATED ZONE BARRELS OPERATE
WITH M-SERIES CONTROLS ONLY

24 VOLT 8 ZONE KIT

8Z-24V

AMZ-24V ZONE CARD
20VA, 240 TO 24 VOLT TRANSFORMER
INSTALLATION INSTRUCTIONS
MOUNTING SCREWS

LENGTH OF ALL BARRELS MEASURE 290 mm.

DIMENSIONS

ALL INTEGRATED ZONE BARRELS COME INDIVIDUALLY 
BOXED FOR SAFE TRANSPORT.

INCLUSIONS: 8Z-24V (8 ZONE KIT)

8Z-24V ZONE MODULE
INSTALLATION INSTRUCTIONS
MOUNTING SCREWS

ITEM

PART NUMBER

7 METER CABLE

4070-004

ZONE MOTOR ONLY

TRANSFORMER ONLY

ZM-24V

2045-046

20 METER CABLE

4070-007

2-WAY RJ45 JOINER

2045-121

3-WAY RJ45 JOINER

4070-008

1.5V

AAA

1.5V

AAA

ZONE 

OPTION 1

TEMPERATURE

AVERAGING ZONE

1

*

All Zone Device Power Cable 

  Cat5E Spec Cables with RJ45 Connectors & Cable Boots - Green Colour

TYPE

10" (250 mm)

PART NUMBER

ZB-10-250

INTEGRATED ZONE BARREL PART NUMBERS

12" (300 mm)

ZB-12-300

Please check prior to purchase.

ActronAir is constantly seeking ways to improve the design of it's products, therefore specifications are subject to change without notice.

ZB-080129

INTEGRATED ZONE BARRELS

12" (300 mm)

10" (250 mm)

16" (400 mm)

14" (350 mm)

14" (350 mm)

16" (400 mm)

ZB-14-350

ZB-16-400

ITEM

PART NUMBER

24 VOLT 4 ZONE KIT

4Z-24V

INCLUSIONS

5 YEAR RESIDENTIAL / 2 YEAR COMMERCIAL
PARTS ONLY WARRANTY

ROBUST METAL BARREL CONSTRUCTION

10 mm FIRE RATED POLYETHELYNE 
INSULATION

7 m CABLE SUPPLIED
(JOINERS AND EXTRA CABLE AVAILABLE)

EASY SNAP-IN WIRING CONNECTION

FAST REACTION TIME

SAFE LOW VOLTAGE (24 VAC)

HIGH TORQUE MOTOR (3 Nm)

DAMPER POSITION INDICATOR

BLADE SEAL INSULATION

FEATURES:

24 VOLT,  3 Nm MOTOR
DRIVE OPEN / DRIVE CLOSE

INSULATED METAL 
ZONE BARREL

7 METER SNAP-IN CABLE

24 VOLT ZONE KIT

NOTE:

THE TOTAL LENGTH OF ALL GREY CABLES CONNECTED
TO THE ZONE MOTORS MUST NOT EXCEED 100 METERS

INCLUSIONS: 4Z-24V (4 ZONE KIT)

NOTE:

WHEN USING INTEGRATED ZONE BARRELS YOU
WILL REQUIRE THE APPLICABLE ZONE KIT. 
(INCLUSIONS & INSTALLATION INSTRUCTIONS 
AS PER DETAILED LIST)

OPTIONAL EXTRAS & SPARE PARTS

INTEGRATED ZONE BARRELS OPERATE
WITH M-SERIES CONTROLS ONLY

24 VOLT 8 ZONE KIT

8Z-24V

AMZ-24V ZONE CARD
20VA, 240 TO 24 VOLT TRANSFORMER
INSTALLATION INSTRUCTIONS
MOUNTING SCREWS

LENGTH OF ALL BARRELS MEASURE 290 mm.

DIMENSIONS

ALL INTEGRATED ZONE BARRELS COME INDIVIDUALLY 
BOXED FOR SAFE TRANSPORT.

INCLUSIONS: 8Z-24V (8 ZONE KIT)

8Z-24V ZONE MODULE
INSTALLATION INSTRUCTIONS
MOUNTING SCREWS

ITEM

PART NUMBER

7 METER CABLE

4070-004

ZONE MOTOR ONLY

TRANSFORMER ONLY

ZM-24V

2045-046

20 METER CABLE

4070-007

2-WAY RJ45 JOINER

2045-121

3-WAY RJ45 JOINER

4070-008

ZONE 

OPTION 2

1.5V

AAA

1.5V

AAA

1.5V

AAA

1.5V

AAA

TYPE

10" (250 mm)

PART NUMBER

ZB-10-250

INTEGRATED ZONE BARREL PART NUMBERS

12" (300 mm)

ZB-12-300

Please check prior to purchase.

ActronAir is constantly seeking ways to improve the design of it's products, therefore specifications are subject to change without notice.

ZB-080129

INTEGRATED ZONE BARRELS

12" (300 mm)

10" (250 mm)

16" (400 mm)

14" (350 mm)

14" (350 mm)

16" (400 mm)

ZB-14-350

ZB-16-400

ITEM

PART NUMBER

24 VOLT 4 ZONE KIT

4Z-24V

INCLUSIONS

5 YEAR RESIDENTIAL / 2 YEAR COMMERCIAL
PARTS ONLY WARRANTY

ROBUST METAL BARREL CONSTRUCTION

10 mm FIRE RATED POLYETHELYNE 
INSULATION

7 m CABLE SUPPLIED
(JOINERS AND EXTRA CABLE AVAILABLE)

EASY SNAP-IN WIRING CONNECTION

FAST REACTION TIME

SAFE LOW VOLTAGE (24 VAC)

HIGH TORQUE MOTOR (3 Nm)

DAMPER POSITION INDICATOR

BLADE SEAL INSULATION

FEATURES:

24 VOLT,  3 Nm MOTOR
DRIVE OPEN / DRIVE CLOSE

INSULATED METAL 
ZONE BARREL

7 METER SNAP-IN CABLE

24 VOLT ZONE KIT

NOTE:

THE TOTAL LENGTH OF ALL GREY CABLES CONNECTED
TO THE ZONE MOTORS MUST NOT EXCEED 100 METERS

INCLUSIONS: 4Z-24V (4 ZONE KIT)

NOTE:

WHEN USING INTEGRATED ZONE BARRELS YOU
WILL REQUIRE THE APPLICABLE ZONE KIT. 
(INCLUSIONS & INSTALLATION INSTRUCTIONS 
AS PER DETAILED LIST)

OPTIONAL EXTRAS & SPARE PARTS

INTEGRATED ZONE BARRELS OPERATE
WITH M-SERIES CONTROLS ONLY

24 VOLT 8 ZONE KIT

8Z-24V

AMZ-24V ZONE CARD
20VA, 240 TO 24 VOLT TRANSFORMER
INSTALLATION INSTRUCTIONS
MOUNTING SCREWS

LENGTH OF ALL BARRELS MEASURE 290 mm.

DIMENSIONS

ALL INTEGRATED ZONE BARRELS COME INDIVIDUALLY 
BOXED FOR SAFE TRANSPORT.

INCLUSIONS: 8Z-24V (8 ZONE KIT)

8Z-24V ZONE MODULE
INSTALLATION INSTRUCTIONS
MOUNTING SCREWS

ITEM

PART NUMBER

7 METER CABLE

4070-004

ZONE MOTOR ONLY

TRANSFORMER ONLY

ZM-24V

2045-046

20 METER CABLE

4070-007

2-WAY RJ45 JOINER

2045-121

3-WAY RJ45 JOINER

4070-008

TYPE

10" (250 mm)

PART NUMBER

ZB-10-250

INTEGRATED ZONE BARREL PART NUMBERS

12" (300 mm)

ZB-12-300

Please check prior to purchase.

ActronAir is constantly seeking ways to improve the design of it's products, therefore specifications are subject to change without notice.

ZB-080129

INTEGRATED ZONE BARRELS

12" (300 mm)

10" (250 mm)

16" (400 mm)

14" (350 mm)

14" (350 mm)

16" (400 mm)

ZB-14-350

ZB-16-400

ITEM

PART NUMBER

24 VOLT 4 ZONE KIT

4Z-24V

INCLUSIONS

5 YEAR RESIDENTIAL / 2 YEAR COMMERCIAL
PARTS ONLY WARRANTY

ROBUST METAL BARREL CONSTRUCTION

10 mm FIRE RATED POLYETHELYNE 
INSULATION

7 m CABLE SUPPLIED
(JOINERS AND EXTRA CABLE AVAILABLE)

EASY SNAP-IN WIRING CONNECTION

FAST REACTION TIME

SAFE LOW VOLTAGE (24 VAC)

HIGH TORQUE MOTOR (3 Nm)

DAMPER POSITION INDICATOR

BLADE SEAL INSULATION

FEATURES:

24 VOLT,  3 Nm MOTOR
DRIVE OPEN / DRIVE CLOSE

INSULATED METAL 
ZONE BARREL

7 METER SNAP-IN CABLE

24 VOLT ZONE KIT

NOTE:

THE TOTAL LENGTH OF ALL GREY CABLES CONNECTED
TO THE ZONE MOTORS MUST NOT EXCEED 100 METERS

INCLUSIONS: 4Z-24V (4 ZONE KIT)

NOTE:

WHEN USING INTEGRATED ZONE BARRELS YOU
WILL REQUIRE THE APPLICABLE ZONE KIT. 
(INCLUSIONS & INSTALLATION INSTRUCTIONS 
AS PER DETAILED LIST)

OPTIONAL EXTRAS & SPARE PARTS

INTEGRATED ZONE BARRELS OPERATE
WITH M-SERIES CONTROLS ONLY

24 VOLT 8 ZONE KIT

8Z-24V

AMZ-24V ZONE CARD
20VA, 240 TO 24 VOLT TRANSFORMER
INSTALLATION INSTRUCTIONS
MOUNTING SCREWS

LENGTH OF ALL BARRELS MEASURE 290 mm.

DIMENSIONS

ALL INTEGRATED ZONE BARRELS COME INDIVIDUALLY 
BOXED FOR SAFE TRANSPORT.

INCLUSIONS: 8Z-24V (8 ZONE KIT)

8Z-24V ZONE MODULE
INSTALLATION INSTRUCTIONS
MOUNTING SCREWS

ITEM

PART NUMBER

7 METER CABLE

4070-004

ZONE MOTOR ONLY

TRANSFORMER ONLY

ZM-24V

2045-046

20 METER CABLE

4070-007

2-WAY RJ45 JOINER

2045-121

3-WAY RJ45 JOINER

4070-008

1.5V

AAA

1.5V

AAA

1.5V

AAA

1.5V

AAA

1.5V

AAA

1.5V

AAA

ZONE 

OPTION 3

2

3

4

5

6

7

8

9

10

11

12

Zone Power Cable 

Cat5E Spec Cables with RJ45 Connectors - Grey Colour

*

*

*

TEMPERATURE

AVERAGING ZONE

ITEM

DESCRIPTION

MAXIMUM CABLE 

LENGTH

1 to 2

1 to 3

8-zone module to 3-way cable joiner (P.N. 4070-012) 

0.175m

1 to 8

8-zone module to zone controller

100m

4 to 8

5 to 10

7 to 12

zone barrel motor to zone device

20m

2 to 9

2 to 11

3-way cable joiner to zone device

20m

TOTAL CABLE LENGTH PER  INDIVIDUAL ZONE (from 8-zone module) MUST NOT 

EXCEED 

100 MTRS

TOTAL LENGTH OF ALL ZONING CABLES (from 8-zone module) MUST NOT 

EXCEED 

250 MTRS. 

 

1.5V

AAA

1.5V

AAA

OR

1.5V

AAA

1.5V

AAA

OR

1.5V

AAA

1.5V

AAA

OR

*

*

Summary of Contents for ESP PLATINUM ERQ2-14AS

Page 1: ... and or reproduction are prohibited without written consent from Actron Air Please Read This Guide Congratulations on your purchase of an Actron Air air conditioning unit This unit has been designed and manufactured with the highest quality standard in mind Please read this guide thoroughly and keep it near the unit for future reference INDOOR UNITS ESP PLATINUM ERQ2 14AS ERQ3 17AS ERQ4 19AS ESP P...

Page 2: ...ety instructions in this literature and all warning labels that are attached to the equipment 2 Prevailing WH S regulations must be observed and will take precedence to the safety instructions contained on this manual Safe work practices and environment must be the paramount importance in the performance of all the service procedures 3 Ensure that unit installation complies with relevant council r...

Page 3: ...o change without notice Copyright 2017 Actron Engineering Pty Ltd Page 3 of 16 COMPONENTS OVERVIEW INDOOR UNIT COMPONENTS OVERVIEW Indoor Unit EC Motor ID Fans ID Coil 8Z VAQ Module Lid Control Panel Indoor Control Panel SRD175C SRD175E DATA DIGITAL SCROLL COMPRESSOR DUCTED UNIT Indoor Unit Control Board EMC Filter ...

Page 4: ...d the outside perimeter is available 4 Minimum service access clearances are responsibilities of the installer ActronAir will not be held liable for any extra charges incurred due to lack of access THIRD ANGLE PROJECTION STACKING OF UNITS ONE IN FRONT OF THE OTHER DISTANCE BET A B SIDE BY SIDE DISTANCE BET A C DUCT WORK 800 mm HEIGHT CLEARANCE 340 B D C A DUCT WORK DUCT WORK 800 mm SERVICE CLEARAN...

Page 5: ...units or between the unit and the outside perimeter is available 4 Minimum service access clearances are responsibilities of the installer ActronAir will not be held liable for any extra charges incurred due to lack of access THIRD ANGLE PROJECTION OVERALL NOMINAL DIMENSION H x W x D 435 x 1420 x 680 SUPPLY DUCT H x W 300 x 715 RETURN DUCT 360 x 1140 DRAIN CONNECTION 20mm OD TOP VIEW FRONT VIEW SI...

Page 6: ...Y PLENUM 2 WAY SUPPLY PLENUM TWIN SPIGOT DUCT PLATE 1 WAY SUPPLY PLENUM UNIT FEATURES flexible ducting Ducting is attached to each section by either a 1 2 or 3 way EASY FIT supply plenum or a twin spigot duct plate these can be fitted to either side of each section ADD ON COOLING is simply achieved by fitting only the coil section into an existing ventilation system Note External static pressure i...

Page 7: ...nt for a clean hygienic room condition Air filters must be placed in an easily accessible location for service and maintenance NOTES 1 Air filters are not supplied with the unit as individual air filtration requirements are varied 2 Ensure that filters are cleaned replaced regularly SUPPLY AIR RETURN AIR DUCT OPTIONAL Supply Air plenums and Duct Plates twin spigot are available in order to facilit...

Page 8: ...riable Refrigeration Capacity Multiple Speed Outdoor Fans SPECIFICATION SUMMARY OUTDOOR UNIT MODEL SRD INDOOR UNIT MODEL SRD R410A DIGITAL SCROLL COMPRESSOR ESP SPLIT DUCTED UNIT 624 675 100 100 100 675 38 38 Fig 2 ELECTRICAL PANEL END INSERT FORKLIFT TINES HERE INSERT FORKLIFT TINES HERE SRD175C SRD175E ELECTION DATA DIGITAL SCROLL SPLIT DUCTED UNIT SRD175C SRD175E ECTION DATA SPECIFICATION SUMMA...

Page 9: ... TRAY DOES NOT OVERFLOW INDOOR COIL RETURN AIR INDOOR COIL CONDENSATE DRAIN MUST BE RUN SEPERATLY FROM THE SAFETY TRAY DRAIN SAFETY TRAY DRAIN CONNECTION CONDENSATE DRAIN CONNECTION SUPPLY AIR INTERNAL CONDENSATE TRAY THE TOP OF THE P TRAP MUST BE 50MM BELOW THE TOP OF THE CONDENSATE DRAIN CONNECTION THE TOP OF THE P TRAP MUST BE 50MM BELOW THE TOP OF THE CONDENSATE DRAIN CONNECTION INSTALL A T PI...

Page 10: ...ONE KIT 8Z 24V AMZ 24V ZONE CARD 20VA 240 TO 24 VOLT TRANSFORMER INSTALLATION INSTRUCTIONS MOUNTING SCREWS LENGTH OF ALL BARRELS MEASURE 290 mm DIMENSIONS ALL INTEGRATED ZONE BARRELS COME INDIVIDUALLY BOXED FOR SAFE TRANSPORT INCLUSIONS 8Z 24V 8 ZONE KIT 8Z 24V ZONE MODULE INSTALLATION INSTRUCTIONS Duct Duct Zone Barrel Damper Motor on Top of the Zone Barrel TYPE 10 250 mm PART NUMBER ZB 10 250 IN...

Page 11: ...REEN WIRE REMOVED ON INDOOR UNIT SCREEN FOIL CLAMPED TO P CLIP ON OUTDOOR UNIT POWER DATA YELLOW CAT5E CABLE POWER ONLY YELLOW CAT5E CABLE MASTER SECONDARY OPTIONAL WiFi WiFi RF RF MODULATION ZONING QUEIB DATA ZONE 8 ZONE 7 ZONE 6 ZONE 5 ZONE 4 ZONE 3 ZONE 2 ZONE 1 TO ZONE 2 8 240V MAINS ZONE MOTOR ZONE CONTROL 1 REMOTE SENSOR 1 LOG RJ45 SOCKETS FOR ACTRON AIR CAT5E SPEC CABLES ONLY REFER TO QUE C...

Page 12: ...lip OUTDOOR UNIT TO OUTDOOR PCB MODEL R 410A CAUTION PLEASE THERE IS NO GAS PRESSURE IN THE FAN COIL UNIT BEFORE REMOVING COPPER END CAPS ENSURE 3670 043 Sensor 4 CAUTION LIVE ELECTRICAL WIRING AUTHORISED TECHNICIANS ONLY INTERNAL CONTROL ISOLATOR FITTED MODEL MEPS CERTIFIED A U S TRALIAN M A D E A U STRALIAN OW N E D R 410A 1 DIAGRAM SHOWING SCREEN FOIL CLAMPING Metal P Clip Electrical Panel 2 CO...

Page 13: ...MEASURE 290 mm DIMENSIONS ALL INTEGRATED ZONE BARRELS COME INDIVIDUALLY BOXED FOR SAFE TRANSPORT INCLUSIONS 8Z 24V 8 ZONE KIT 8Z 24V ZONE MODULE INSTALLATION INSTRUCTIONS MOUNTING SCREWS ITEM PART NUMBER 7 METER CABLE 4070 004 ZONE MOTOR ONLY TRANSFORMER ONLY ZM 24V 2045 046 20 METER CABLE 4070 007 2 WAY RJ45 JOINER 2045 121 3 WAY RJ45 JOINER 4070 008 ZONE OPTION 2 1 5V AAA 1 5V AAA 1 5V AAA 1 5V ...

Page 14: ...ng Panels and Frames Visual check for damage rust and dust accumulation For highly corrosive environment wash panels quarterly with water neutral detergent solution Wax panels Repair re paint where required Insulation Visual check for insulation conditions Repair replace insulation material Fan Visual check for run out of balance and dust attached Clean off dust as necessary to negate possibility ...

Page 15: ...ESCRIPTION PART NUMBER QUANTITY QUANTITY QUANTITY 1 EC ID Fan 2520 333 1 1 2 EC ID Fan 2520 334 1 3 Indoor Coil Assembly 1040 156 1 4 Indoor Coil Assembly 1040 254 1 5 Indoor Coil Assembly 1040 177 1 6 Coil Piston 4540 088 1 7 Coil Piston 4540 098 1 8 Coil Piston 4540 128 1 9 ID Control Board AFS QUEIB1 1 2020 154 1 1 1 10 Zone Module 8Z VAQ 1 1 1 11 Filter Board 4080 013 1 1 1 12 Yellow Cat5e Cab...

Page 16: ...Ltd ABN 34 002 767 240 HEAD OFFICE SYDNEY AUSTRALIA Printed in Australia Part No 0525 052 Rev No 4 0 180302 1800 119 229 actronair com au Copyright 2017 Actron Engineering Pty Ltd Refrigerant Trading Authorisation No AU06394 ...

Reviews: