background image

www.acti.com

 
 

Hardware Manual 

               

18 

Manually adjust the IP addresses of multiple cameras 

If there are more than one camera to be used in the same local area network and there is no 

DHCP server to assign unique IP addresses to each  of them, all of the cameras would then 

have the initial IP address of 

192.168.0.100

, which is not a proper situation for network devices 

– all the IP addresses have to be different from each other. The easiest way to assign cameras 

the IP addresses is by using 

IP Utility

 

 

 

With the procedure shown above, all the cameras will have unique IP addresses, starting from 

192.168.0.101. In case there are 20 cameras selected, the last one of the cameras would have 

the IP 192.168.0.120. 

 

Later,  by  pressing  the 

“Refresh”  button  of  the  IP  Utility,  you  will  be  able  to  see  the  list  of 

cameras with their new IP addresses. 

 

Please  note  that  it  is  also  possible  to  change  the  IP  addresses  manually  by  using  the  Web 

browser. In such case, please plug in only one camera at a time, and change its IP address by 

using the Web browser before plugging in the next one. This way, the Web browser will not be 

confused about two devices having the same IP address at the same time. 

 

Summary of Contents for Q970

Page 1: ...Intercom Camera Hardware Manual Q970 2022 03 23...

Page 2: ...tallation 9 Step 2 Mount the Camera 9 Step 3 Connect the Camera 9 Step 4 Access the Camera Live View 10 Cable Connections 11 Connecting a Power Adapter Optional 11 Connecting DI DO Devices Optional 12...

Page 3: ...g or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Trademarks ACTi and ACTi logo are registered trademarks of ACTi Corporation...

Page 4: ...urning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation be...

Page 5: ...vicing Do not attempt to service this product yourself Refer all servicing to qualified service personnel Damage Requiring service Disconnect this product from the power supply immediately and refer s...

Page 6: ...www acti com Hardware Manual 6 Introduction The List of Models This hardware manual contains the following models Q970 2MP Intercom Basic WDR Superior Low Light Sensitivity...

Page 7: ...7 Package Contents Check if the camera package comes with the following items Camera Screws and Plugs Drill Template 10 Pin Terminal Block 6 Pin Terminal Block Quick Installation Guide Warranty Card...

Page 8: ...RS 485 protocol can also be connected here See Cable Connections on page 11 6 Power LED Lights red when the camera is powered up 7 Memory Card Slot Insert a memory card not included into the slot for...

Page 9: ...drill template Step 2 Mount the Camera 1 Mount the camera body through the hole 2 Attach the four 4 screws to secure the camera on the surface NOTE The device front panel is waterproof However you mu...

Page 10: ...ng a Power Adapter Optional on page 11 for more information 3 As needed connect and power up other devices such as digital input output audio or serial device See Cable Connections on page 11 for more...

Page 11: ...af compliant In case of using a non PoE switch or your PoE switch has limited power supply you can purchase a power adapter and directly connect the camera to a power outlet The power adapter must be...

Page 12: ...of the camera work Some devices may not have Normal Close and Normal Open switches thus only have DC12V and GND wire connectors In this case map the wires according to the diagram below DI Connection...

Page 13: ...slot then release the orange tab to secure the wire Then connect the terminal block to the camera Via RS 485 Connection Pin Label Camera Serial Device GND GROUND PIN D TX DATA D TX DATA NOTE The pins...

Page 14: ...d slot until it clicks into place Once inserted make sure to access the camera Web Configurator and mount the card to prepare the card for local recording Refer to the camera Firmware User s Manual fo...

Page 15: ...d the PC would request a unique IP address from the DHCP server automatically In such case the camera will immediately be ready for the access from the PC The user however might not know the IP addres...

Page 16: ...numbers firmware versions etc and allows quick configuration of multiple devices at the same time Search and downloand IP Utility for free from http www acti com DownloadCenter When you launch IP Util...

Page 17: ...o the network and it does not detect any DHCP services it will automatically assign itself a default IP 192 168 0 100 Whereas the default port number would be 80 In order to access that camera the IP...

Page 18: ...IP Utility With the procedure shown above all the cameras will have unique IP addresses starting from 192 168 0 101 In case there are 20 cameras selected the last one of the cameras would have the IP...

Page 19: ...ion Detection regions Privacy Mask regions Yes All the other configurations Yes When using Internet Explorer browser the ActiveX control for video stream management will be downloaded from the camera...

Page 20: ...IP address since the default HTTP port of the camera is 80 which can be omitted from the address for convenience Before logging in you need to set up the root Account and Password of the camera The pa...

Page 21: ...Copyright 2022 ACTi Corporation All Rights Reserved 7F No 1 Alley 20 Lane 407 Sec 2 Ti Ding Blvd Neihu District Taipei Taiwan 114 R O C TEL 886 2 2656 2588 FAX 886 2 2656 2599 Email sales acti com...

Reviews: