Connecting DI/DO Devices (Optional)
Depending on your needs, you may connect digital input/output devices, such as alarm to the
camera.
Check the device documentation for the pin mapping specifications. Map the pins of the device
to the supplied terminal block pins accordingly. Then connect the terminal block to the camera.
Below is a diagram on how the Digital Output of the camera work.
Some devices may not have Normal Close and Normal Open switches, thus only have DC12V
and GND wire connectors. In this case, map the wires according to the diagram below.
DI
Connection design
TTL-compatible logic levels
Voltage
To trigger (low)
Logic level 0:
0V ~ 0.4V
Normal (high)
Logic level 1:
3.1V ~ 30V
Current
10mA ~ 100mA
DO
Connection design
Form C Solid-State Relay
Isolation test voltage 3750 VRMS
Typical RON 20
DC or peak AC load voltage 350 V
Continuous DC load current (form C
operation) 15 mA
Output power dissipation (continuous)
600 mW
Voltages accepted
350V AC/DC, 0.15A
(COM)