5.4 Error limits of the level display
SPM-32A ... SPM-36A
5-10
5.4.3
Total error
(the total of all previously listed errors)
SPM-32A/-33A/-36A:
Table 5-9
Total error (SPM-32A/-33A/-36A)
Error limits
(selective)
1
f=200 Hz to 620 kHz
±
0.7 dB
±
1.1 dB
f=200 Hz to 1.62 MHz
±
0.9 dB
±
1.3 dB
f=50 Hz to 2 MHz
±
1.0 dB
±
1.4 dB
f=50 Hz to 3 MHz
±
1.1 dB
±
1.5 dB
f=50 Hz to 3.5 MHz
±
1.3 dB
±
1.7 dB
Error limits
(wideband)
2
f=200 Hz to 620 kHz
±
0.8 dB
—
—
f=200 Hz to 1.62 MHz
±
1.0 dB
—
—
f=200 Hz to 2 MHz
±
1.1 dB
—
—
f=200 Hz to 3 MHz
±
1.2 dB
—
—
f=200 Hz to 3.5 MHz
±
1.4 dB
—
—
Level range/dBm
(75, 135, 150
Ω
)
+20
-40
-80
-90
1
1. RMS measurement
Level range/dB, dBm (600
Ω
)
+10
-50
-90
-100
2
2. Average measurement, display of rms value for sinusoidal signals