4.4
The person at the door cannot hear PC User
Increase the Microphone sensitivity in Audio Settings.
Also check the following:
1. Ensure that the Speaker Grill is fitted securely against the Door
Entry Panel Grill.
2. Check the Door Entry Panel Grill for any blockages.
3. Check that the supply voltage is not at an inadequate level. For
best operation it should be between 10V and 15V between
terminals and -12V on the speech unit.
4. Check the handset connections to the PC are correct.