Charging Recommendations
Charging liquid in a CONTROLLED manner into the suction side until the system is full.
This recommen-
dation does not hold true for reciprocaing compressors where liquid charging into the suction side could cause
severe damage.
Charging Cylinder on Scale
Close-up of Scale
Carefully monitor the suction and discharge pressures - ensure that the suction pressure does not fall below
psig (.7 bar) at any time during the charging process.
CAUTION :
Manifold Gauge will show cylinder pressure rather than suction pressure if the cylinder valve and
Manifold valve “A” are both open.
There are many ways of charging liquid in a “controlled manner” into the
suction side:-
. Use valve A on the manifold gauge set
. Use the valve on the refrigerant cylinder
. Charge through a Shredder valve
. Use a hose with a Shredder valve depressor
. Charge into the suction side at some distance from the compressor
. All of the above
A
Charging Procedures -Three phase compressors
The fundamental procedure is the same as for single phase models but the compressor can run in the wrong
direction on starting. If this happens reverse any two phases and start again. Short term reverse rotation will
not damage the compressor.
As compressors get larger the importance of correct field charging procedures grows exponentially.
Unfortu¬nately larger systems are often field charged which leads to many infant failures. All Specter
compressors have internal discharge temperature protectors which are very effective in preventing
dangerously high discharge temperatures during charging. The protection module will trip and lock the
compressor out for 0 minutes. It is not normally necessary to wait 0 minutes for the module to reset. When the
compressor has cooled down the module can be reset by breaking the power supply to the control circuit. Very
often the serviceman does not understand why the module tripped and uses a jumper wire to bypass it. He
continues to charge the system and removes the jumper when charging is complete. The compressor may or
may not run with the protector back in the circuit but it is certain that the compressor has been damaged and
premature failure is inevitable.
Summary of Contents for A4MC 100ER
Page 1: ...Ceiling Concealed D Series ACC D2 2007 ACC 75 D DR ACC100 D DR Models ...
Page 50: ...48 Model AMC A4MC 75 100D ER Note All Dimension are in mm Outdoor Unit ...
Page 53: ...51 Model ACC 75 100D vs AMC A4MC 75 100D Cooling Only 10 WIRING DIAGRAMS ...
Page 54: ...52 Heat Pump Model ACC 75 100DR vs Model AMC A4MC 75 100ER ...