Versatile Feed Roll 5” Dia
CI0183670000
•
07-18-2019
33
Problem
Possible Cause
Possible Remedy
Stalling
Overfeeding
Reduce feed rate
Wrapping of material
Strippers are worn down; either
readjust or replace.
Insufficient tension on chain drive,
slippage and burning
Check chain tension and adjust as
required
Installation fault, motor is running in
reverse direction
Check the direction of the drive
sprocket and reset electrical
connections to correct rotational
direction
Bearing overheating
Inadequate lubrication
Over lubrication
Check lubrication frequency and the
recommended lubricants in motor and
roller bearings
Dirt/Contamination in bearing
Eliminate source of contamination
Motor fails to start
Power supply failure.
Check fuses.
Starter is inoperative.
Check supply mains. Also, check
starter contacts for burning, replace if
necessary.
Motor fails to start
Motor starts, but will not
take load.
Starter overloads cut out.
Check current requirements on motor
nameplate and adjust.
Safety interlock is inoperative.
Check and adjust as needed.
Too much chain tension.
Check chain tension and adjust as
necessary.
Motor is improperly wired.
Check terminal connection with
manufacturer’s connection diagram in
conduit box and adjust as necessary.
Motor starts, but will not
take load.
Motor starts when
disconnected from load, but
will not when connected.
Defective starter winding.
Check current in each phase with an
ammeter. If there is marked difference
in current on any phase, contact the
motor manufacturer.
Worn bearings.
Check and replace if necessary, in
accordance with manufacturer’s
literature.
Summary of Contents for FRV Seroes
Page 36: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 36...
Page 37: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 37 7 2 Technical Specifications...
Page 38: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 38...
Page 39: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 39...
Page 40: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 40...
Page 41: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 41...
Page 42: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 42...
Page 44: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 44 Sheet 1 of 2...
Page 45: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 45 Sheet 2 of 2...
Page 46: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 46 7 4 Pneumatic Circuit Diagram...