Versatile Feed Roll 5” Dia
CI0183670000
•
07-18-2019
25
Chapter 4:
Operation
4-1 Start-up
PULSE-STARTING THE MOTOR
•
If the motor is turning in the proper direction, pulse-start the motor, regardless of
desired speed.
•
Pulse-start the motor by providing full current (60Hz) to the motor through the VFD.
Allow the motor to run and full speed before adjusting the VFD for the desired feed
rate.
4-2 Operation Procedures
Never reach beyond the infeed entrance while the machine is running.
To clear a jam, refer to the procedure for clearing a jam, which is Sect. 5-1: Clearing a Jam.
Avoid excessive feed rates. Feed rates in excess of rated capacity may cause the machine to
stall or jam.
4-3 Air Cylinder Adjustment
The feed nip should be run at the minimum air pressure necessary to pull the web into the
granulator. The chart below shows the load across every inch of a 50” wide web for a given
air pressure. If too much air pressure is used, the operator runs the risk of embedding the
knurled pattern into the material and causing the web to stick to the rolls and wrap them.
Summary of Contents for FRV Seroes
Page 36: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 36...
Page 37: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 37 7 2 Technical Specifications...
Page 38: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 38...
Page 39: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 39...
Page 40: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 40...
Page 41: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 41...
Page 42: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 42...
Page 44: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 44 Sheet 1 of 2...
Page 45: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 45 Sheet 2 of 2...
Page 46: ...Versatile Feed Roll 5 Dia CI0183670000 07 18 2019 46 7 4 Pneumatic Circuit Diagram...