background image

EXP-06E Access Control System Installation Instruction 

 

Satcom Systems (International) Co., Ltd.        

15 

 

Model : SFLA-030-2L

Switching Power Supply

DC1   +12V(2A)
DC2   -12V (1A)

AC -L

D C 2

AC -N

C O M

D C 1

F G

Connected to EXP-06 Controller Board

12V A (+)

12V B (-)

12V Output for Electric Lock (2 am p.)

12V (+)

12V (-)

AC220V Input

JP

3

J

P

7

C5

Parallel Printer

Battery

JP1

25 pin

9 pin

RS485

RS232

R

AB

C

D

E

F

G

H

I

K

L

M

O

P

N

JQ

1

1

71

8

7

JP

2

DATA 1 / STROBE
DATA 0 / DATA

BEEPER
NOT USE/ CARD PRESENT

LED

GND
+VDC

READE

R

(I

N

)

READE

R

(O

U

T

)

Door Release Button

Door Sensor

2
3

5

6

5

Door Lock Relay Output

Program m able Relay Output

Alarm  Relay Output

IBM Com patible PC

KE

Y PAD

JP14

DATA 1 / STROBE
DATA 0 / DATA

BEEPER
NOT USE/ CARD PRESENT

LED

GND
+VDC

RAM

Program

Chip

EXP-06E Controller Board

CPU

I/O 2

I/O
 1

JP15
JP8
JP18
JP12

COM

DC2

C1

C2

C3

C4

JP5

1

3

JP4

1

3

232

75176

JP4 & JP5

Enable RS485

JP4 & JP5

Enable RS232

5VDC Output for Reader Supply

12VDC Output for Reader Supply

Sort Using Battery for Data Mem ory

JP1

3   1

3   1

JP16

Door Lock Relay Output  (NO)

Door Lock Relay Output  (NC)

JP2

Program mable Relay Output (NO)

Program mable Relay Output  (NC)

JP3

Alarm  Relay Output (NO)

Alarm  Relay Output  (NC)

JP7

Sort

Open

JP15

W atch Dog

Active

Deactive

JP8

Duress Alarm

Disable

Enable

JP18

- -

- -

JP12

12VDC

ON

OFF

RS232 Com m unication

C4

9 PIN

25 PIN

G

3

2

H

2

3

I

5

7

RS485 Com m unication

C4

RS485/RS232 Converter

E

RS485 (-)

F

RS485 (+)

 

Summary of Contents for EXP-06E

Page 1: ...Access Control System EXP 06E Single Door Access Controller Installation and Operation Instructions Version 6 6 Revision 2003 5...

Page 2: ...t sensors such as intrusion motion detectors door contacts low temperature and can activate cameras or lighting controls automatically unattended The ACS access Control System provides user with much...

Page 3: ...rsion Motherboard 1 x RS232 port Display SVGA 800x600 resolution color monitor with 16 bits color Input Device Enhanced 101 keyboard and serial mouse Floppy Disk 1 x 3 5 high density floppy disk drive...

Page 4: ...9 Pin Entry Time Zone 3 Cardholder Authority Levels 3 Holidays 100 IN Reader Can be using LED Indication Lamp with Keypad OUT Reader Only LED Indication Lamp System Characteristics Multiple Technolog...

Page 5: ...232 RS485 Converter Modem Modem Telephone Line EXP 06E EXP 06E 1 32 RS232 RS485 Converter EXP 06E EXP 06E 1 32 E E D D D D Communication Configurations E Wire Label From To Function Gauge AWG No of Pa...

Page 6: ...ly 6 3 Single Pin Code Entry Only At this operation mode users can key in the card number through keypad instead of card operation Press key will enable this function if this operation is set If user...

Page 7: ...proximity card reader s LED light will hold on 5 seconds to green color user should release key 0 button in the keypad and key in 4 digits the current used pin code If the key in pin code is correct...

Page 8: ...code is 0001 then the duress pin code should be 0002 i e If the user pin code is 9999 then the duress pin code should be 0000 6 9 Double Pin Code Entry for Duress Pin Code If duress alarm function in...

Page 9: ...l The EXP 06E has two types of battery backup onboard memory and operational power The operational power battery known as the Advanced Power Supply APS gives the EXP 06E internal power fail capability...

Page 10: ...l diode parallel to the door lock 2 ATTENEION It may affect the performance of EXP 06E when diode is not installed parallel to the lock See Figure 1 2 7 3 3 Door Release Button Door Sensor 1 Connect o...

Page 11: ...ommunication using the RS 232C communication using the RS 485 communication protocol set jumpers JP4 JP5 to 1 2 position 7 4 2 RS 232C Connection Table Pin connection EXP 06E Pin Signal DB25 DB9 Host...

Page 12: ...r Model ic485Ip 1F Table Pin connection EXP 06E Pin Converter E 2 4 Sort F 1 3 Sort 7 5 Connection with Advanced Power Supply Option The Power Supply Board provides uninterrupted power backup of EXP 0...

Page 13: ...put the time sec at the Door Open Alarm field in Software and also connect the Door Sensor to the controller 3 Duress Alarm If the door is opened with key in the duress pin code the alarm relay will b...

Page 14: ...1 Memory 32KB Clock Data Memory back up battery Non charge 1 month backup during power failure Communication Interface RS232 and RS485Converter type Data Transfer Rate Local Remote 9 600 bps Input Vol...

Page 15: ...tput Alarm Relay Output IBM Compatible PC KEY PAD JP14 DATA 1 STROBE DATA 0 DATA BEEPER NOT USE CARD PRESENT LED GND VDC RAM Program Chip EXP 06E Controller Board CPU I O 2 I O 1 JP15 JP8 JP18 JP12 CO...