![Acrosser Technology ANR-C236N1-K1D00 User Manual Download Page 52](http://html1.mh-extra.com/html/acrosser-technology/anr-c236n1-k1d00/anr-c236n1-k1d00_user-manual_2841642052.webp)
ANR-C236N1-K Series User Manual
52
Acrosser Technology Co., Ltd.
Contents in 7Bh (STATUS_IOUT) Command Code:
Bit Number
Status Bit Name
Meaning
[7:6]
Reserved
Return=0
5
+12V_OC_WARNING
+12V_IOUT > Max Current of
110%@1Sec = 1 ; Normal = 0
[4:0]
Reserved
Return=0
Contents in 7Dh (STATUS_TEMPERATURE) Command Code:
Bit Number
Status Bit Name
Meaning
[7:3]
Reserved
Return=0
3
AMBIENT_OT_FAULT
Ambient temperature >60°C = 1 ; Normal =0
2
AMBIENT_OT_WARNING
Ambient temperature >55°C = 1 ; Normal = 0
[1:0]
Reserved
Return=0
Contents in 80h (STATUS_OF_3V3 And 5V) Command Code:
Bit Number
Status Bit Name
Meaning
7
5V_OC_ FAULT
5V_IOUT > Max Current of 130%@ 1Sec = 1 ;
Normal = 0
6
3V3_OC_FAULT
3V3_IOUT > Max Current of 130%@ 1Sec = 1 ;
Normal = 0
5
5V_UV_WARNING
VOUT < 4.5V = 1 ; Normal = 0
4
3V3_UV_WARNING
VOUT < 3.0V = 1 ; Normal = 0
3
5V_OV_WARNING
VOUT > 5.5V = 1 ; Normal = 0
2
5V_OC_WARNING
5V_IOUT > Max Current of 110%@ 1Sec = 1 ;
Normal = 0
1
3V3_OV_WARNING
VOUT > 3.6V = 1 ; Normal = 0
0
3V3_OC_WARNING
3V3_IOUT > Max Current of 110%@ 1Sec = 1 ;
Normal = 0
Contents in B0h (PSU_STATUS) Command Code:
Bit Number
Status Bit Name
Meaning
[7:4]
Reserved
Return=0
3
PSU2 PRESENT
Module Plug OUT = 1 ; Module Plug IN = 0
2
PSU1 PRESENT
Module Plug OUT = 1 ; Module Plug IN = 0
1
PSU2 STATUS
FAIL = 1 ; OK = 0
0
PSU1 STATUS
FAIL = 1 ; OK = 0