ANR-C236N1-K Series User Manual
50
Acrosser Technology Co., Ltd.
Command
Code
Command Name
Data Format
Number of
Data Bytes
8Dh
READ_TEMPERATURE_1
(2)
Read Linear
2
96h
READ_+12V_POUT
Read Linear
2
99h
MFR_ID
Read ASCII
6
9Ah
MFR_MODEL
Read ASCII
13
9Bh
MFR_REVSION
Read ASCII
2
9Eh
MFR_SERIAL
Read ASCII
12
A7h
MFR_POUT_MAX
Read Linear
2
A8h
MFR_TAMBIENT_MAX
Read Linear
2
B0h
PSU_STATUS
Read Byte
1
D1h
READ_TOTAL_POUT (3)
Read Linear
2
D2h
READ_3V3_VOUT
Read VOUT Mode
2
D3h
READ_3V3_IOUT
Read Linear
2
D4h
REDA_3V3_POUT
Read Linear
2
D5h
READ_5V_VOUT
Read VOUT Mode
2
D6h
READ_5V_IOUT
Read Linear
2
D7h
READ_5V_POUT
Read Linear
2
FBh
Buzzer_Mute (4)
R/W Byte
1
Note 1:
Status will retain the last occurrence. Latch defined as the status. Must be cleared
through the 03h (CLEAR_FAULTS) command. Please See the following Table.
Command
Status Name
Status action
79h
STATUS_WORD
Latch
7Ah
STATUS_VOUT
Latch
7Bh
STATUS_IOUT
Latch
7Dh
STATUS_TEMPERATURE
Latch
80h
STATUS_OF_3V3 And 5V
Latch
B0h
PSU_STATUS
Automatic recovery
Note 2: READ_TEMPERATURE_1 should provide the PDB Inlet Ambient temperature.
Note 3: Read Total Power command only at +12 V, 3V3, 5V total power.
Note 4: Buzzer will alert when any PSU fault occurs. Write 0x20 command in PMBus will be
able to mute buzzer alarm. When PSU goes back to normal state, the register will be
set at 0x00.