28
the printing upwards. Decrease the value to move the printing
downwards. Increasing the value by 1 moves the print 0.002"
upwards. Decreasing the value by 1 moves the print 0.002"
downwards. Press the E button to accept the value and register
the setting.
4.3 Synchronizing the minute and second
The ATR 440 allows for easy time synchronization with other
devices such as another clock or signaling device.
To synchronize the ATR 440, open the top cover. The digital
display reads P1.
Press the PRO button twice. The display should
now read P3.
Press the F3 button to advance the clock one minute at a time.
The clock will begin at 00 seconds. Each time the F3 button is
pressed, the clock advances one minute.
4.4 Seconds reset - allows you to synchronize to the second
Open the top cover. The digital display reads P1.
Press the PRO button twice. The display should
now read P3.
Press the F4 button to reset the seconds back to 0. The clock will
automatically restart.
Special functions
atr440 A5 paper size.p65
8/21/02, 8:16 AM
28