WARNING: This board utilizes 
static sensitive components 
and should only be handled at 
a static-safe workstation.

 

mishandling during transit.  If the shipping carton is badly damaged or water 
stained, request that the carrier's agent be present when the carton is 
opened.  If the carrier's agent is absent when the carton is opened and the 
contents of the carton are damaged, keep the carton and packing material 
for the agent's inspection.  

For repairs to a product damaged in shipment, refer to the Acromag Service 
Policy to obtain return instructions.  It is suggested that salvageable shipping 
cartons and packing material be saved for future use in the event the 
product must be shipped.  

This board is physically protected with packing material and electrically 
protected with an anti-static bag during shipment.  However, it is 
recommended that the board be visually inspected for evidence of 
mishandling prior to applying power. 

 

Card Cage Considerations 

 

Refer to the specifications section for loading and power requirements.  Be 
sure that the system power supplies are able to accommodate the power 
requirements of the system boards, plus the installed Acromag board, 
within the voltage tolerances specified. 

In an air cooled assembly, adequate air circulation must be provided to 
prevent a temperature rise above the maximum operating temperature and 
to prolong the life of the electronics.  If the installation is in an industrial 
environment and the board is exposed to environmental air, careful 
consideration should be given to air-filtering. 

In a conduction cooled assembly, adequate thermo conduction must be 
provided to prevent a temperature rise above the maximum operating 
temperature. 

Board Installation 

 

Remove power from the system before installing board, cables, termination 
panels, and field wiring. 

 
P15 Primary XMC Connector 

 

The P15 primary XMC connector connects directly to the T4 ASIC via eight 
lanes of Gen 2 PCI Express. The connector pin out, complies with the 
ANSI/VITA 42.3-2006 pin definitions. Note that the XMC-6280 does not 
support wakeup functionality and does not have a 3.3V aux line. 

This XMC connector is a 114-pin Samtec ASP-103614-05 connector. The 
connector complies with the ANSI/VITA 42.3-2006. 

 

 

Summary of Contents for XMC-6280 Series

Page 1: ...le USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 2014 Acromag Inc Printed in the USA Data and specifications are subje...

Page 2: ...6 2 0 PREPARATION FOR USE 6 Unpacking and Inspecting 6 Card Cage Considerations 7 Board Installation 7 P15 Primary XMC Connector 7 SFP Module Connector 8 Non Isolation Considerations 8 3 0 SOFTWARE D...

Page 3: ...Repair Assistance 17 Preliminary Service Procedure 17 Where to Get Help 18 6 0 SPECIFICATIONS 18 PHYSICAL 18 POWER REQUIREMENTS 18 ENVIRONMENTAL 19 Terminator 4 ASIC U1 19 P15 XMC Connector 20 SFP Co...

Page 4: ...erform satisfactory overall system design and it is agreed between you and Acromag that this is your responsibility The information of this manual may change without notice Acromag makes no warranty o...

Page 5: ...rd hardware that off loads TCP IP iSCSI FCoE and iWARP RDMA processing from its host system The XMC 6280 frees up host CPU cycles for useful applications As a result the system achieves increased band...

Page 6: ...RDMA on a single unified wire DDR3 SDRAM Provides 64 Meg x 72 bit DDR3 SDRAM The SDRAM is linked to the ASIC device for the storage of the ASIC s internal microprocessor firmware data buffers and con...

Page 7: ...CIe PCIe Gen 2 is also backwards compatible with Gen 1 however the use of Gen 1 will also result in significantly reduced performance Software Requirements Supported operating systems and functions va...

Page 8: ...e specifications section for loading and power requirements Be sure that the system power supplies are able to accommodate the power requirements of the system boards plus the installed Acromag board...

Page 9: ...round 11 VeeR Module Receiver Ground 12 RD Receiver Inverted Data Output 13 RD Receiver Non Inverted Data Output 14 VeeR Module Receiver Ground 15 VccR Module Receiver 3 3 V Supply 16 VccT Module Tran...

Page 10: ...www acromag com 9 www acromag com 3 0 SOFTWARE DRIVER INFORMATION Software Driver Download from Linux Source Tarball 1 Go to http service chelsio com and search the downloads as shown below 2 In the S...

Page 11: ...com 10 www acromag com 3 Read and accept the Chelsio End User License Agreement 4 Download the Chelsio support documentation including the README Release Notes and User Guide Refer to the User Guide...

Page 12: ...Download for Windows Operating Systems 1 Go to http service chelsio com downloads Microsoft to download the latest Windows Unified Wire driver Refer to the README file for information on supported op...

Page 13: ...cromag Inc Tel 248 295 0310 12 http www acromag com 12 www acromag com 3 Run the ChelsioUwire x x x xx exe installer application Refer to the User Guide for information on how to properly install and...

Page 14: ...d on the board is also provided Refer to the XMC 6280 Block Diagram shown below as you review this material CARRIER BOARD CHELSIO T4 ASIC 675 pin FCBGA SERIAL EEPROM SERIAL FLASH 50MHz XTAL P15 SFP 10...

Page 15: ...16D5 The board contains four small form factor pluggable plus SFP connectors and cage assemblies that accept SFP modules as well as SFP modules The SFP interfaces are wired directly to the T4 ASICs in...

Page 16: ...elf the EEPROM is read first to get configuration information Then the ASIC copies the firmware from the flash to DDR3 memory and runs everything from there This Serial EEPROM is not intended to be re...

Page 17: ...C P15 connector VPWR_5 12 pins The VPWR_5 12 power is the V in voltage to the three LTM4602 devices U16 U17 and U18 and also to the LTM4601 devices U19 and U21 The LTM4602 devices output 2 5V 1 5V and...

Page 18: ...oning board be returned to Acromag for repair The board can be easily damaged unless special SMT repair and service tools are used Further Acromag has automated test equipment that thoroughly checks t...

Page 19: ...ule Unit Weight 4 9144oz 139 32g POWER REQUIREMENTS If you continue to have problems your next step should be to visit the Acromag worldwide web site at http www acromag com Our web site contains the...

Page 20: ...ucted R F Immunity CRFI Complies with IEC 61000 4 6 with no register upsets Surge Immunity Not required for signal I O per IEC 61000 4 5 Electric Fast Transient EFT Immunity Complies with IEC 61000 4...

Page 21: ...hardware configuration and PCIe configuration information It also contains the T4 ASIC firmware configuration data 32Mb Flash 32Mb 4Mb x 8 Micron M25P32 Serial Flash contains the T4 s internal microp...

Page 22: ...lied as a way to monitor the temperature of the ASIC and is connected to the thermal pins of the Chelsio T4 ASIC PCIe Bus Interface XMC Compatibility Conforms to PCI Express Base Specification v2 0 an...

Page 23: ...SERIAL EEPROM SERIAL FLASH 50MHz XTAL P15 SFP 10GBPS XMC PCIe to 4 FIBER 10 GBPS Ethernet PCIE 2 0 x8 SMB DDR III 1600 64Meg X 16 SFP 10GBPS SFP 10GBPS SFP 10GBPS I2C I2C MDIO GPIO XFI XFI XFI XFI Eth...

Page 24: ...ss to Sanitize Power Down Non Volatile Memory Does this product contain Non Volatile memory i e Memory of whose contents is retained when power is removed Yes No Type EEPROM Flash etc Flash Size 32Mbi...

Page 25: ...l Acromag release 1 MAY 14 B EZ EZ Added power requirements Theory of Operation temperature sensor and MAC address information Revised Environmental conditions involving immunities and emissions 2 Oct...

Reviews: