XMC-6280
USER’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 19 - http://www.acromag.com
- 19 -
www.acromag.com
ENVIRONMENTAL
Terminator 4 ASIC (U1)
On Board 1.0V Power to
T4 ASIC
Current Rating
(available for the T4 ASIC)
1.0V (
5%)
12A typical
24A maximum
Operating Temperature
Model
Operating Temperature
XMC-6280-LF
-20
C to 70
C
Relative Humidity:
5-95% Non-Condensing.
Storage Temperature:
-55
C to 100
C.
Non-Isolated:
PCIe bus and field commons have a direct electrical
connection.
Radiated Field Immunity (RFI):
Complies with IEC 61000-4-3 with no
register upsets.
Conducted R F Immunity (CRFI):
Complies with IEC 61000-4-6 with no
register upsets.
Surge Immunity:
Not required for signal I/O per IEC 61000-4-5.
Electric Fast Transient (EFT) Immunity:
Complies with IEC 61000-4-4 Level 3
(1.0KV at field I/O terminals).
Electrostatic Discharge (ESD) Immunity:
Complies with EN61000-4-2 Level
3 (8KV enclosure port air discharge) Level 2 (4KV enclosure port contact
discharge).
Radiated Emissions:
Meets or exceeds European Norm 61000-6-3:2007 for
class A equipment. Shielded cable with I/O connections in shielded
enclosure is required to meet compliance.
The Chelsio fourth generation Terminator 4 ASIC is a 27x27mm 675-pin
FCBGA package with a 8-lane PCIe Gen2 interface to the server and four
1GbE/10GbE MACs on the network side.