XMC-6260-CC
USER’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 8 -
http://www.acromag.com
- 8 -
www.acromag.com
This XMC connector is a 114-pin Samtec ASP-103614-05 connector. The
connector complies with the ANSI/VITA 42.3-2006.
P16 Secondary XMC Connector
Table 2.4:
P16 XMC
Connector pin definitions
.
*These pins are reserved for future use by the VITA 42.6 XMC 10 Gigabit
Ethernet 4-lane Protocol Layer Standard.
X(2:3)_RD[0:3]. Link 2 and 3 Differential Receive.
These signals are used by
the XMC to receive high-speed protocol-specific data from the carrier over
Link 2 and 3. These signals tolerate EIA-644 signal levels.
X(2:3)_TD[0:3]. Link 2 and 3 Differential Transmit.
These signals are used by
the XMC to transmit high-speed protocol-specific data from the carrier over
Link 2 and 3. These signals tolerate EIA-644 signal levels.
A
B
C
D
E
F
01 X2_TD0p
X2_TD0n
NC
X2_TD1p
X2_TD1n
NC
02
GND
GND
NC
GND
GND
NC
03 X2_TD2p
X2_TD2n
NC
X2_TD3p
X2_TD3n
NC
04
GND
GND
NC
GND
GND
NC
05 X3_TD0p
X3_TD0n
NC
X3_TD1p
X3_TD1n
NC
06
GND
GND
NC
GND
GND
NC
07 X3_TD2p
X3_TD2n
NC
X3_TD3p
X3_TD3n
NC
08
GND
GND
NC
GND
GND
NC
09
RFU*
RFU*
NC
RFU*
RFU*
NC
10
GND
GND
NC
GND
GND
NC
11 X2_RD0p X2_RD0n
NC
X2_RD1p X2_RD1n
NC
12
GND
GND
NC
GND
GND
NC
13 X2_RD2p X2_RD2n
NC
X2_RD3p X2_RD3n
NC
14
GND
GND
NC
GND
GND
NC
15 X3_RD0p X3_RD0n
NC
X3_RD1p X3_RD1n
NC
16
GND
GND
NC
GND
GND
NC
17 X3_RD2p X3_RD2n
NC
X3_RD3p X3_RD3n
NC
18
GND
GND
NC
GND
GND
NC
19
RFU*
RFU*
NC
RFU*
RFU*
NC
Non-Isolation Considerations
The board is non-isolated, since there is electrical continuity between the
logic and field I/O grounds. As such, the field I/O connections are not
isolated from the system. Care should be taken in designing installations
without isolation to avoid noise pickup and ground loops caused by multiple
ground connections.