APPENDIX
CABLE: MODEL 5028-187 (SCSI-2 to Flat Ribbon, Shielded)
Type
Round shielded cable, 50-wires (SCSI-2 male connector at one end and a flat
female ribbon connector at the other end). The cable length is 2 meters
(6.56 feet). This shielded cable is recommended for all I/O applications
(both digital I/O and precision analog I/O).
Application
Used to connect Model 5025-552 termination panel to the TRANS-200
Transition Module. The transition module then connects to all four IP
module slots to the rear of the AVME9670A (Slots A-D).
Length
Standard length is 2 meters (6.56 feet). Consult factory for other lengths. It
is recommended that this length be kept to a minimum to reduce noise and
power loss.
Cable
50 conductors, 28 AWG on 0.050 inch centers (permits mass termination for
IDC connectors), foil/braided shield inside a PVC jacket.
Headers
(One End): SCSI-2, 50-pin male connector with backshell and spring latch
hardware.
(Other End): IDC, 50-pin female connector with strain relief.
Keying
The SCSI-
2 connector has a “D Shell” and the IDC connector has a polarizing
key to prevent improper installation.
Schematic and Physical Attributes: See Drawing 4501-758.
Shipping Weight
1.0 pound (0.5Kg), packed.
Termination Panel Model 5025-552
Type
Termination Panel For AVME967xA Boards
Application
To connect field I/O signals to the Industrial I/O Pack (IP).
Termination
Panel:
Acromag Part 4001-040 (Phoenix Contact Type FLKM 50). The 5025-
552 termination panel facilitates the connection of up to 50 field I/O signals
and connects to the TRANS-200 transition module via a cable (Model 5028-
187). Field signals are accessed via screw terminal strips. The terminal strip
markings on the termination panel (1-50) correspond to P2 (pins 1-50) on
the Industrial I/O Pack (IP). Each Industrial I/O Pack (IP) has its own unique
P2 pin assignments. Refer to the IP module manual for correct wiring
connections to the termination panel.
Field Wiring
50-position terminal blocks with screw clamps. Wire range 12 to 26 AWG.
Connections to AVME9670A
P1, 50-pin male header with strain relief ejectors. Use Acromag 5028-187
cable to connect panel to TRANS-200 transition module. Keep cable as
short as possible to reduce noise and power loss.