CABLE:  MODEL 5028-187 (SCSI-2 to Flat Ribbon, Shielded)

Type:  Round shielded cable, 50-wires (SCSI-2 male connector at

one end and a flat female ribbon connector at the other end).
The cable length is 2 meters (6.56 feet).  This shielded cable is
recommended for all I/O applications (both digital I/O and
precision analog I/O).

Application:  Used to connect Model 5025-552 termination panel to

the TRANS-200 Transition Module.  The transition module then
connects to all four IP module slots to the rear of the AVME9670
or AVME9675-4 (Slots A-D).  The AVME9675-2 uses IP slots
A-B.

Length:  Standard lenght is 2 meters (6.56 feet).  Consult factory for

other lenghts.  It is recommended that this length be kept to a
minimum to reduce noise and power loss.

Cable:  50 conductors, 28 AWG on 0.050 inch centers (permits

mass termination for IDC connectors), foil/braided shield inside
a PVC jacket.

Connectors:  (One End):  SCSI-2, 50-pin male connector with

backshell and spring latch hardware.

      (Other End):  IDC, 50-pin female connector with strain

relief.

Keying:  The SCSI-2 connector has a “D Shell” and the IDC

connector has a polarizing key to prevent improper installation.

Schematic and Physical Attributes:  See Drawing 4501-758.
Electrical Specifications:  30 VAC per UL and CSA (SCSI-2

connector spec.’s).  1 Amp maximum at 50% energized
(SCSI-2 connector spec.’s).

Operating Temperature: -20

°

C to +80

°

C.

Storage Temperature:  -40

°

C to +85

°

C.

Shipping Weight:  1.0 pound (0.5Kg), packed.

TERMINATION PANEL:  MODEL 5025-552

Type:  Termination Panel For Carrier Boards
Application:  To connect field I/O signals to the Industrial I/O Pack

(IP).  Termination Panel:  Acromag Part 4001-040  (Phoenix
Contact Type FLKM 50).  The 5025-552 termination panel
facilitates the connection of up to 50 field I/O signals and
connects to the TRANS-200 transition module via a cable
(Model 5028-187). Field signals are accessed via screw terminal
strips.  The terminal strip markings on the termination panel (1-
50) correspond to P2 (pins 1-50) on the Industrial I/O Pack (IP).
Each Industrial I/O Pack (IP) has its own unique P2 pin
assignments.  Refer to the IP module manual for correct wiring
connections to the termination panel.

Schematic and Physical Attributes:  See Drawing 4501-464.
Field Wiring:  50-position terminal blocks with screw clamps.  Wire

range 12 to 26 AWG.

Connections to TRANS-200 Transition Module:  P1, 50-pin male

header with strain relief ejectors.  Use Acromag 5028-187 cable
to connect panel to TRANS-200 transition module.   Keep cable
as short as possible to reduce noise and power loss.

Mounting:  Termination panel is snapped on the DIN mounting rail.
Printed Circuit Board:  Military grade FR-4 epoxy glass circuit board,

0.063 inches thick.

Operating Temperature:  -40

°

C to +100

°

C.

Storage Temperature:  -40

°

C to +100

°

C.

Shipping Weight:  1.25 pounds (0.6kg) packed.

VME64x TRANSITION MODULE: MODEL TRANS-200

Type:  Transition module for AVME9670, AVME9675-4, and

AVME9675-2 boards.

Application:  To repeat field I/O signals of IP modules A through D

for rear exit from VME64x card cages.  This module is available
for use in card cages which provide rear exit for I/O connections
via 80 mm wide transition modules (transition modules can only
be used in card cages specifically designed for them). It is a
double-height (6U), single-slot module with front panel hardware
adhering to the VME64x bus mechanical dimensions and IEEE
Standard (1101.11-1998), for 80 mm depth.  Connects to
Acromag termination panel 5025-552 from the rear of the card
cage, and to AVME9670 & AVME9675 boards within card cage,
via connectors RP0 and RP2.

Schematic and Physical Attributes:  See Drawing 4501-760.
Electrical Specifications:  30 VAC per UL and CSA (SCSI-2

connector spec.’s).  1 Amp maximum at 50% energized
(SCSI-2 connector spec.’s).

Field Wiring:  Four SCSI-2, 50-pin female connectors (AMP

787082-5 or equivalent) employing latch blocks and 30 micron
gold in the mating area (per MIL-G-45204, Type II, Grade C).
Connects to Acromag termination panel 5025-552 from the rear
of the card cage via round shielded cable (Model 5028-187).

Connections to AVME9670 & AVME9675: Connections are made

though the PC board connectors RP0 (95 pin female with upper
ground shield) and RP2 (160 pin female).  The transition module
plugs directly behind the AVME9670 or AVME9675 board into
the VME64x bus backplane within the card cage system.

Mounting:  Transition module is inserted into a 6U-size, 80 mm

width slot at the rear of the VME64Xbus card cage. (Directly
behind AVME9670 or AVME9675 board).

Printed Circuit Board:  Eight-layer, military-grade FR-4 epoxy glass

circuit board, 0.063 inches thick.

Operating Temperature: -40

°

C to +85

°

C.

Storage Temperature:  -40

°

C to +85

°

C.

Shipping Weight:  1.25 pounds (0.6Kg) packed.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for AMVE9675-4E

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...D 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 2000 Acromag Inc Printed in the USA Data and specifications are subject to change without not...

Page 3: ...Access LEDs and Pulse Stretcher Circuitry 16 Power Supply Filters 16 Power Supply Fuses 16 5 0 SERVICE AND REPAIR 16 SERVICE AND REPAIR ASSISTANCE 16 PRELIMINARY SERVICE PROCEDURE 16 6 0 SPECIFICATIO...

Page 4: ...leverage to install and remove the board VME64x bus INTERFACE FEATURES Slave Module CR CSR Registers A24 D16 D08 O Carrier Register Short I O Access A16 D16 D08 O IP Module ID Space A16 D16 D08 O IP...

Page 5: ...ove the maximum operating temperature The dense packing of the IP modules to the carrier board restricts air flow within the card cage and is cause for concern Adequate air circulation must be provide...

Page 6: ...onfiguration is required All interrupt enabling status and VME64x bus interrupt level selections are configured via programmable registers on the carrier board see Section 3 for programming details Th...

Page 7: ...3 3V 19 RsvBus GND AM3 A19 RsvBus 20 GND IACK GND A18 3 3V 21 RsvBus IACKIN SERA A17 RsvBus 22 GND IACKOUT SERB A16 3 3V 23 RsvBus AM4 GND A15 RsvBus 24 GND A07 IRQ7 A14 3 3V 25 RsvBus A06 IRQ6 A13 R...

Page 8: ...uires that the bus master drive the system reset for the first 200mS after power up thus inhibiting any data transfers from taking place IP control registers are also reset following a power up sequen...

Page 9: ...r 0x000000 0x00 00 00 8 bytes 0x5F to 0x7B RESERVED 0x00 00 1 byte 0x7F Program ID code 0x00 24 bytes 0x83 to 0xDF Unimplemented 0x00 00 CR Offset Address MSB LSB Content Description ROM Data MSB LSB...

Page 10: ...onds to the geographic address of slot 3 per section 3 2 11 of the VME64x standard The AVME9675 will parity check the geographical address If bad parity is detected the local address will be set to de...

Page 11: ...dard A24 address space if needed for IP modules containing Memory space IP memory will only be mapped into the standard memory space if it is enabled for a particular IP per the user programmable IP M...

Page 12: ...ill not be latched or registered on the carrier An interrupt will only remain set as pending on the carrier if its corresponding IP module has an active interrupt request Bit 6 Auto Acknowledge Disabl...

Page 13: ...space for IP D A zero disables memory space accesses Reset Condition Set to 0 memory space accesses disabled for IP D Bit 2 IP C Memory Enable Read Write Writing a 1 to this bit enables the memory sp...

Page 14: ...system software to define a base address for the AVME9675 carrier and IP module registers Once the carrier board is mapped to the desired base address communication with its registers and the I O and...

Page 15: ...Master to control and communicate with electronic devices that are external to the VME64x bus card cage The external electronic hardware may linked to the carrier board rear access via a transition m...

Page 16: ...rt address space Access up to 8Mbytes of IP data mapped to Memory Space via D16 or D08 EO transfers using VME64x bus A24 standard address space Respond to two IP module interrupt requests per IP with...

Page 17: ...ds typical Power Supply Filters Power line filters are dedicated to each IP module for filtering of the 5 12 and 12 volt supplies The power line filters are a T type filter circuit comprising ferrite...

Page 18: ...0nS Typical all carrier board registers measured from the falling edge of DSx to the falling edge of DTACK 450nS Typical IP registers with no wait states See IP specifications for information on wait...

Page 19: ...e logic and field side the field I O connections are not isolated from the VME64x bus Radiated Field Immunity RFI Designed to comply with IEC1000 4 3 Level 3 10V m at frequencies 27MHz to 500MHz and E...

Page 20: ...64 Field Wiring 50 position terminal blocks with screw clamps Wire range 12 to 26 AWG Connections to TRANS 200 Transition Module P1 50 pin male header with strain relief ejectors Use Acromag 5028 187...

Page 21: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 20 4501 800A Artisan Technology Group Quality Instrumentation Guaranteed 888...

Page 22: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 21 4501 801A Artisan Technology Group Quality Instrumentation Guaranteed 888...

Page 23: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 22 4501 802A Artisan Technology Group Quality Instrumentation Guaranteed 888...

Page 24: ...IES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 23 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 S...

Page 25: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 24 4501 464A Artisan Technology Group Quality Instrumentation Guaranteed 888...

Page 26: ...VME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ 25 4501 760B Artisan Technology Group Quality Instrumentation Guaranteed 888...

Page 27: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: