background image

AP5080E / AP580-POE AcroPack   

USER

’S MANUAL 

 

 

 

 

 

 

 

Acromag, Inc. Tel: 248-295-0310  

            - 17 -                                   

http://www.acromag.com  

- 17 - 

https://www.acromag.com 

 

 

 

4.3.2    Other Environmental Requirements 

 

4.3.2.1   Relative Humidity 

 

The range of acceptable relative humidity is 5% to 95% non-condensing. 

4.3.2.2   Isolation 

 

POE Output voltage, 100VDC 

4.3.3   Vibration and Shock Standards 

 

The AcroPack is designed to comply with the following Vibration and Shock 
standards. 

 

Vibration, Operating: 

MIL-STD-810G, Method 514.6  

Procedure I (General Vibration)  
Category 20 (Ground vehicles/ground mobile)  
8-500Hz, Sinusoidal 5Grms X, Y and Z axis. 1hr per axis (15 minute sweep up 
/ 15 minute sweep down test duration) 

Shock, Operating: 

MIL-STD-810G, Method 516.6  

Procedure I (functional Shock)  
50g, 11ms half-sine 3 positive/negative per axis (Total of 18 drops) 

4.3.4   EMC Directives 

 

The AcroPack is designed to comply with EMC Directive 2004/108/EC. 

 

Immunity per EN 61000-6-2:

 

 

Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.  

 

Radiated Field Immunity (RFI), per IEC 61000-4-3.  

 

Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4.  

 

Surge Immunity, per IEC 61000-4-5.  

 

Conducted RF Immunity (CRFI), per IEC 61000-4-6. 

 

Emissions per EN 61000-6-4:

 

 

Enclosure Port, per CISPR 16.  

 

Low Voltage AC Mains Port, per CISPR 16.  

 

Note: 

This is a Class A product

 

 

 

 

Summary of Contents for AcroPack AP580E

Page 1: ...net Module USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0310 Email solutions acromag com Copyright 2016 Acromag Inc Printed in the USA Data and speci...

Page 2: ...els 4 1 3 1 Ordering Information 4 1 3 2 Key Features 4 1 3 3 Key Features PCIe Interface 5 1 4 Signal Interface Products 5 1 5 Software Support 5 1 6 Introduction 5 2 0 PREPARATION FOR USE 6 2 1 Unpa...

Page 3: ...16 4 2 2 POE Power Output to PD device 16 4 3 Environmental Considerations 16 4 3 1 Operating Temperature 16 4 3 2 Other Environmental Requirements 17 4 3 2 1 Relative Humidity 17 4 3 2 2 Isolation 1...

Page 4: ...pdate or keep current the information contained in this manual No part of this manual may be copied or reproduced in any form without the prior written consent of Acromag 1 2 1 Trademark Trade Name an...

Page 5: ...POE Power over Ethernet as a PSE Power sourcing Device end point Is designed to meet IEEE 802 3af standard 10 Watt Limited using a Linear Technology Single POE PSE controller 1 3 1 Ordering Informati...

Page 6: ...onnected the module is accessed via a 50 pin or 68 pin panel connector The cables and termination panels are also available 1 5 Software Support The AcroPack series AP580 require support drivers speci...

Page 7: ...near strong electrostatic electromagnetic magnetic or radioactive fields unless the device is contained within its original manufacturer s packaging Be aware that failure to comply with these guideli...

Page 8: ...able to accommodate the power requirements of the system boards plus the installed Acromag board within the voltage tolerances specified In an air cooled assembly 200 LFM of air circulation is recomme...

Page 9: ...ignal pin assignments for the module field I O connector Every other pin of the 100 pin connector is left unconnected in order to meet the minimum distance required for 60 Volt isolation Table 2 1 Fie...

Page 10: ...33 16 29 32 Reserved isolation 31 Reserved isolation 9 9 17 34 43 34 18 33 36 Reserved isolation 35 Reserved isolation 10 10 19 38 44 35 20 37 40 Reserved isolation 39 Reserved isolation 11 11 21 42 4...

Page 11: ...Reserved isolation 63 Reserved isolation 17 17 33 66 LAN LINK 100 LED 51 42 34 65 68 Reserved isolation 67 Reserved isolation 18 18 35 70 LAN LINK 1000 LED 52 43 36 69 72 Reserved isolation 71 Reserve...

Page 12: ...rrier Connector 2 Ribbon Carrier Connector 1 Module P2 Pin Number Field Signal Name 58 49 48 93 GND 96 GND 95 GND 25 25 49 98 GND 59 50 50 97 GND 100 GND 99 GND Note 1 VPX4500 CC LF is an example of a...

Page 13: ...me Pin Name 51 5V 1 2 52 3 3V3 49 12V 1 2 50 GND 47 12V 1 2 48 1 5V 1 45 Present4 46 LED_WPAN 1 43 GND 44 LED_WLAN 1 41 3 3V3 42 LED_WWAN 1 39 3 3V3 40 GND 37 GND 38 USB_D 1 35 GND 36 USB_D 1 33 PETp0...

Page 14: ...oPack family of carrier boards are generally difficult to repair The board can be easily damaged unless special SMT repair and service tools are used For these and other reasons it is strongly recomme...

Page 15: ...ation for Use section have been followed Also refer to the documentation of your carrier board to verify that it is correctly configured Replacement of the board with one that is known to work correct...

Page 16: ...https www acromag com 4 0 SPECIFICATIONS 4 1 Physical Height 10 8 mm 0 4921 in Height defines Carrier to Module Maximum component height Board Thickness 1 0 mm 0 03937 in AcroPack L x W 70 mm x 30 00...

Page 17: ...t 40 C to 70 C AP580E POE LF 1 2 1Gb Ethernet with POE 40 C to 70 C Note 1 The AP580 does not support the AcroPack Accessory AP CC 01 Conduction cool kit Note 2 200LFM minimum Air flow is required abo...

Page 18: ...mobile 8 500Hz Sinusoidal 5Grms X Y and Z axis 1hr per axis 15 minute sweep up 15 minute sweep down test duration Shock Operating MIL STD 810G Method 516 6 Procedure I functional Shock 50g 11ms half...

Page 19: ...382 5 298 4 1 FIT is Failures in 109 hours AP580E POE LF MTBF Mean Time Between Failure MTBF in hours using MIL HDBK 217F FN2 Per MIL HDBK 217 Ground Benign Controlled GBGC Temperature MTBF Hours MTB...

Page 20: ...Yes No Function Process to Sanitize Type SRAM SDRAM etc Size User Modifiable Yes No Function Process to Sanitize Non Volatile Memory Does this product contain Non Volatile memory i e Memory of whose c...

Page 21: ...YYYY Version EGR DOC Description of Revision 12 JUL 2017 A PDG ARP Initial Release 23 OCT 2017 B CAB ARP Section 1 5 Software Support updated to include link to download driver 30 NOV 2017 C PDG ARP...

Reviews: