AP580E / AP580E-POE AcroPack
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 16 -
- 16 -
https://www.acromag.com
4.2 Power Requirements
4.2.1 POE Power Requirements
+12VDC @1.5A (minimum)
4.2.2 POE Power Output (to PD device)
52VDC @ .193A (Max) 10 watts
DC isolation is limited to 100VDC, this limitation is due to the signal paths of
the PCB.
4.3 Environmental Considerations
4.3.1 Operating Temperature
Model Number
Description
Temp Range
AP580E-LF
1
1Gb Ethernet
-40°
C
to 70°
C
AP580E-POE-LF
1,2
1Gb Ethernet with POE
-40°
C
to 70°
C
Note 1
: The AP580 does not support the AcroPack Accessory AP-CC-01
(Conduction cool kit).
Note 2
: 200LFM (minimum) Air flow is required above
50°
C
Summarized below are the expected current draws for each of the specified
power supply voltages.
Power Supply Voltage Current Draw
•
+3.3 VDC +/- 5%
1
115 mA (max)
•
1.5 VDC Not Used
•
5.0 VDC Not Used
•
+12 VDC Not Used
•
-12 VDC Not Used
Note 1
:
Typical current draw is using an AP580 with
APCe
7020E-LF
Summarized below are the operating temperature range, airflow and other
environmental requirements and applicable standards for the AcroPack
module.