AP512 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 36 - http://www.acromag.com
- 36 -
https://www.acromag.com
5.0 SPECIFICATIONS
5.1 Physical
Height
(carrier to top of module components)
: 12.5 mm (0.4921 in) [MAX]
Board Thickness:
1.0 mm (0.03937 in)
Length x Width:
70.0 mm x 30.0 mm (2.76 in x 1.18 in)
Unit Weight
(not including shipping material)
: 8.3g (0.293 oz)
5.2 Power Requirements
5.3 Environmental Considerations
5.3.1 Operating Temperature
All modules have an operational temperature range of -40°C to 85°C
1,2
.
Note 1
: An air cooled application with an AcroPack module will require a
minimum airflow of 200LFM.
Note 2
: A conduction cooled application with an AcroPack module will
require purchase of the Heatsink
AP-CC-01
.
Table 5.1 Model
ID
Summarized below are the expected current draws for each of the specified power
supply voltages.
Power Supply
Voltage
Current Draw (Idle/Typical)
1
3.3 VDC ± 5%
100/450mA
5.0 VDC ± 5%
NOT USED
1.5 VDC ± 5%
NOT USED
12 VDC ± 5%
NOT USED
-12 VDC ± 5%
NOT USED
Note 1
:
Idle current draw was measured with no external loopbacks or termination installed and
no active communication on any port.
Typical current draw was measured with external loopbacks and 100ohm line
termination installed on every module port, actively running a loopback test using
Passmark Burn-In Test.
Summarized below are the operating temperature range, airflow and other
environmental requirements and applicable standards for the AcroPack
module.