54
bits
170
0xAA
First channel
communication baud
rate
R/W
0-38400,1-19200,2-9600,3-
4800,4-2400,5-1200
word
171
0xAB
First channel
communication address
R/W
1-247
word
172
0xAC
reserve
R/W
word
173
0xAD
First channel
communication parity
bits
R/W
0-No check
,
1-2stop bit
,
3-Odd
,
4-Even
word
174
0xAE
First channel
communication baud
rate
R/W
0-38400,1-19200,2-9600,3-
4800,4-2400,5-1200
,
6-Profibus
word
175
0xAF
First channel
communication address
R/W
1-247
word
176-177
0XB0-0
xB1
reserve
R/W
word
178
0xB2
Start mode
R/W
0-Protection
mode,
1-manual mode, 2-two-step
mode, 3-two-speed mode,
4-star-triangle
mode,
5-auto-step-down
word
179
0xB3
Control access
R/W
0-panel
;
1-in place
;
2-communication
;
3-remote
;
4-three choice
one;5-two choice one;6-all
control
word
180
0xB4
Start 1 delay
R/W
0.1-60.0s
word
181-189
0xB5-0x
BD
reserve
R/W
word
190
0xBE
DO type
R/W
0:Open 1:Closed
,
bit0-4
:
relay output1-5
word
191
0xBF
DO1 action setting
R/W
0-Level
;(
3-250
)
-pulse
time
,
unit:0.1S
word
192
0xC0
DO2 action setting
R/W
0-Level
;(
3-250
)
-pulse
time
,
unit:0.1S
word
193
0xC1
DO3 action setting
R/W
0-Level
;(
3-250
)
-pulse
time
,
unit:0.1S
word
194
0xC2
DO4 action setting
R/W
0-Level
;(
3-250
)
-pulse
time
,
unit:0.1S
word
195
0xC3
DO5 action setting
R/W
0-Level
;(
3-250
)
-pulse
time
,
unit:0.1S
word
196
0xC4
DO2 programmable
setting
R/W
Alarm
:
correspond to alarm
allowed bit 1
word
197
0xC5
R/W
Trip
:
correspond to trip
allowed bit 1
word
198
0xC6
R/W
0-No input, 1-star 1, 2-start
2,3-start3,
4-parking,5-starting jumped
contactor,6-circuit
breakers,7-fault Alarm
output,8-tripping fault
word