VENTILATION
A minimum of 100 cm
2
purpose provided ventilation is required for this appliance. This may be achieved
either with one vent 100 cm
2
at a high or low position in the room, or split ventilation i.e. 50cm
2
be
installed at high level and 50cm
2
be installed at low level within the room. An openable window or
equivalent is also required.
To reduce the possibility of draughts, road noise or insects entering the room via the air vent, we rec-
ommend the use of “Black Hole”, “Vortex” or “Centurion” type vents featuring internal baffles. The
requirements of any other gas, oil or solid fuel appliances operating in the same room or space must
be taken into consideration when assessing ventilation.
Any ventilation fitted must comply with BS5871 part 4 and BS 5440 part 2.
Ventilation fitted under, or within immediate vicinity of the appliance must not be used as it may
adversely effect performance of the ODS system. For Republic of Ireland refer to the current edition of
IS813 and any relevant rules in force. The appliance shall not be installed within one metre of any
existing air vent, and any new air vent shall not be installed within one metre of the appliance.
UNPACKING THE APPLIANCE
Lift off the remaining packaging components. Check that the components supplied correlate with the
component checklist. Please dispose of all the packaging materials at your local recycling centre.
COMPONENT CHECKLIST
APPLIANCE INSTALLATION
Note: Ensure that the gas supply is isolated before commencing installation of the appliance.
The fireplace opening and environment must be in compliance with specifications laid down in the
appropriate sections of these instructions.
PREPARING THE APPLIANCE
Remove the appliance from its carton as described previously and stand on a dustsheet. Remove the
hood and glass panel and place safely to one side.
Knock out holes are provided in the rear and sides of the firebox for use where concealed pipework is
required. Note: Knock out holes are also provided in the sides of the inner firebox if a side-entry pipe
routing is required, but it is essential to seal these holes with grommets. Knock out the appropriate
hole in the cavity box with a sharp tap from a hammer and fit the rubber grommet supplied. A small
incision can now be made in the rubber to slip snugly around the outside of the supply pipe and sleev-
ing.
Warning : Do not install or use the appliance without this seal in place.
5.0
5.1
6.0
6.1
4.1
QUANTITY DESCRIPTION
1
Firebox and burner assembly
1
Set of manufacturer’s instructions
1
Traditional Gunmetal Frame with integral front (XF-EROT-F models)
1
Contemporary Black Frame with separate front (XF-EROC-B models)
1
Contemporary Stone-effect Frame with separate front (XF-EROC-B models)
1
Rubber grommet
1
Cable fixing kit
1
Screw pack including fibre rawlplugs
Screw pack consists of:
2
No. 8 pozi self tapping screws
5
©
2011 Acquisitions of London