INSTALLATION INSTRUCTIONS
Place the pump in the sump; make sure that nothing interferes
with switch operation.
3.
CAUTION:
Make sure the pump cannot move in the sump. If the
pump moves when it runs, the piping or sump wall may interfere
with the switch and prevent the pump from starting or stopping
causing a risk of flooding.
Finish installing the necessary plumbing. Follow the pipe glue
manufacturer's instructions for safety precautions and curing
time.
4.
Power Supply: This pump requires a 115V, 60Hz, 15 amp individual branch circuit. The circuit must be
grounded and should be dedicated to the sump pump.
The pump is supplied with a 3-wire cord set with grounding- type plug. Insert
the switch plug directly into the outlet then insert the pump plug into the back
of the switch plug.
5.
Pump Plug
Switch Plug
CAUTION:
To avoid the risk of electrical shock, always ground the pump to a
suitable electrical ground, such as a grounded metal water pipe, a properly
grounded metallic raceway, or a ground wire system. Do not cut off the round
ground pin from the pump or switch plugs.
3