Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
©2010 ACP, Inc.
16400009
25
Illustration
Component
Testing
Results
Fuse block / Filter assembly
Power In terminals ......................................
Power Out terminals ...................................
120 VAC
120 VAC
If no power in, check power outlet
If no power out, check fuses
Interlock switch assembly
Disconnect wires to switch.
With door open measure resistance from:
Monitor – Terminals 3 - 4 ...................
Primary – Terminals 1 - 2 ...................
Secondary – Terminals 5 - 6 ..............
With door closed measure resistance
from:
Monitor – Terminals 3 - 4 ...................
Primary – Terminals 1 - 2 ...................
Secondary – Terminals 5 - 6 ..............
After verifying or replacing the module,
re-connect wires to switch and check
operation of monitor circuit before
operating the oven.
Indicates continuity
Infinite
Ω
Infinite
Ω
Infinite
Ω
Indicates continuity
Indicates continuity
Indicates continuity